SECTION 2: SAFETY & EMC INSTRUCTIONS
DS2100 User's Manual
C27750-001 PAGE 2-11
The following table details the recommended cable dimensions for all DS2100 models
DS2100 Models Notes
µ
µµ
µA
A B
Cable
3/11 AWG
(mm
2
)
6/22 AWG (mm
2
) 8/22 AWG (mm
2
) 14/42 AWG (mm
2
)
Line Power 3x14 (2.1) 3x14 (2.1) 3x14 (2.1) 3x12 (3.3)
Protective Bonding Cable 1x 6 (13) 1x 6 (13) 1x 6 (13) 1x 6 (13)
Motor Power Cable 4x14 (2.1) 4x14 (2.1) 4x14 (2.1) 4x12 (3.31) Shielded
Regen Resistor Cable 2x14 (2.1) 2x14 (2.1) 2x14 (2.1) 2x14 (2.1) Shielded
DC Bus Cable 2x14 (2.1) 2x14 (2.1) 2x14 (2.1) 2x14 (2.1) Shielded
Safety Interlock (If applicable) 2x22 (0.3) Shielded
24V Power Cable 2x14 (2.1) Shielded
Note: 2x14 (2.08) = Number of conductors x conductor size (AWG = American wire gauge)
DS2100 Models Notes
C D
Cable 20/45
AWG
(mm
2
)
25/70
AWG
(mm
2
)
30/90
AWG
(mm
2
)
50/140
AWG (mm
2
)
60/180
AWG (mm
2
)
Line Power 3x8 (8.4) 3x8 (8.4) 3x8 (8.4) 3x 6 (13) 3x 4 (21)
Protective Bonding Cable 1x 6 (13) 1x 6 (13) 1x 6 (13) 1x6 (13) 1x4 (21)
Motor Power Cable 4x8 (8.4) 4x8 (8.4) 4x8 (8.4) 4x6 (13) 4x4 (21) Shielded
Regen Resistor Cable 2x8 (8.4) 2x8 (8.4) 2x8 (8.4) 2x 6 (13) 2x4 (21) Shielded
DC Bus Cable 2x8 (8.4) 2x8 (8.4) 2x8 (8.4) 2x 6 (13) 2x4 (21) Shielded
Safety Interlock (If applicable) 2x22 (0.3) Shielded
24V Power Cable 2x14 (2.1) Shielded
DS2100 Models Notes
E
Cable 10
0/300
AWG (mm
2
)
Line Power 3 x 1 (42)
Protective Bonding Cable 1 x 1 (42)
Motor Power Cable 4 x 1 (42) Shielded
Regen Resistor Cable 2 x 2 (34) Shielded
DC Bus Cable 2 x 1 (42) Shielded
Safety Interlock (If applicable) 2x22 (0.3) Shielded
24V Power Cable 2 x 14 (2.1) Shielded
Table 2.2 DS2100 Cable Dimensions