User`s manual

DS2100 User's Manual SECTION 5: DS2100 FUNCTIONAL OVERVIEW
PAGE 5-34
Index Type Name
0x2C2E/1 U08 hardware_enable_configuration
0x2C2E/2 U08 hardware_enable_debounce_count
0x2C2E/3 U08 hardware_enable_invert
0x2C2E/25 U08 hardware_enable_control
0x2C2E/4 U08 digital_input_1_configuration
0x2C2E/5 U08 digital_input_1_debounce_count
0x2C2E/6 U08 digital_input_1_invert
0x2C2E/26 U08 digital_input_1_control
0x2C2E/7 U08 digital_input_2_configuration
0x2C2E/8 U08 digital_input_2_debounce_count
0x2C2E/9 U08 digital_input_2_invert
0x2C2E/27 U08 digital_input_2_control
0x2C2E/10 U08 digital_input_3_configuration
0x2C2E/11 U08 digital_input_3_debounce_count
0x2C2E/12 U08 digital_input_3_invert
0x2C2E/28 U08 digital_input_3_control
0x2C2E/13 U08 digital_input_4_configuration
0x2C2E/14 U08 digital_input_4_debounce_count
0x2C2E/15 U08 digital_input_4_invert
0x2C2E/29 U08 digital_input_4_control
0x2C2E/16 U08 digital_input_5_configuration
0x2C2E/17 U08 digital_input_5_debounce_count
0x2C2E/18 U08 digital_input_5_invert
0x2C2E/30 U08 digital_input_5_control
0x2C2E/19 U08 digital_input_6_configuration
0x2C2E/20 U08 digital_input_6_debounce_count
0x2C2E/21 U08 digital_input_6_invert
0x2C2E/31 U08 digital_input_6_control
0x2C2E/22 U08 digital_input_7_configuration
0x2C2E/23 U08 digital_input_7_debounce_count
0x2C2E/24 U08 digital_input_7_invert
0x2C2E/32 U08 digital_input_7_control
0x2C2D/1 U08 digital_input_status_word
Table 5.16 List of Digital Input Parameters
5.10.1.1 Digital Input Function Assignment
Setting the digital input configuration entry for the digital input, to the appropriate handler function number,
configures the functionality of each input. The table below lists the functions that can be assigned. Only the NULL
function can be assigned to more than one digital input. If an attempt is made to map a function twice a mapping
error is indicated.
For Edge Triggering:
The handler function is not called repetitively, but rather the handler function is called when: -
Initially setting up the digital input, when no previous function assigned to the input (i.e first time).
A transition occurs in the digital input.
Change the setting of the digital input invert.