5.6.1.12 Set Encoder Position
Encoders with a Hiperface or EnDat digital interface provide the facility to be able to set the datum position from
which the absolute position is measured. This feature is supported using the parameter encoder_set_position.
5.6.1.13 Encoder EEPROM Enable
Encoders with a Hiperface or EnDat digital interface provide onboard EEPROM for parameter storage. This can be
used by the DS2100 to store motor related parameters so that a drive can be replaced while retaining the motor
setup. The EEPROM parameter storage is enabled by setting the parameter encoder_eeprom_enable to 1. This
parameter is set to 0 by default.
The parameters stored in the encoder EEPROM are:
encoder supply
encoder offset
commutation feedback source
commutation offset
motor number of poles
motor Rtt
motor Lq
motor Ld
motor Ke
motor maximum current
motor maximum velocity
motor velocity limit
current limit mask
bus over-voltage limit
regen off voltage
regen on voltage
current loop d-axis i-gain
current loop d-axis p-gain
current loop q-axis i-gain
current loop q-axis p-gain
current loop alpha observer i-gain
current loop alpha observer p-gain
current loop beta observer i-gain
current loop beta observer p-gain
motor sensor coefficient a0
motor sensor coefficient a1
motor sensor coefficient a2
motor sensor coefficient a3
motor sensor minimum temperature
motor sensor maximum temperature
motor max temperature
thermal limit motor start temperature
thermal limit motor span temperature