User`s manual
SECTION 4: GETTING STARTED
DS2100 User's Manual
C27750-001 PAGE 4-17
4.15 Oscilloscope
4.15.1 Oscilloscope Set-up
Open the oscilloscope, “DS2100
→
Oscilloscope”
The Status prompt in the lower right hand corner should be yellow and read “initialising”
Set-up Channels 1-3, Timebase and Trigger as per the table 1 below,
Figure 4.27 Oscilloscope
Channel 1 Channel 2 Channel 3 Timebase Trigger
Status
Visible Visible Visible ------------ ------------
Source
Demand Velf Iqact ------------ Demand
Scaling
200000000 / div 20 / div 5 A / div 0.002 s / div ------------
Delay ------------ ------------ ------------ ------------ Delay - 0.002 s
Coupling ------------ ------------ ------------ ------------ DC
Slope
------------ ------------ ------------ ------------ Rising
Mode
------------ ------------ ------------ ------------ Single
Table 1 Oscilloscope Channel Set-up