SECTION 4: GETTING STARTED
PAGE 4-8 C27750-001
4.7 Regen Resistor Configuration
Only the µA size DS2100 is equipped with an internal regeneration resistor. The larger sizes (A-D) require an external
resistor to be attached. The recommended regeneration resistors are detailed in Section 5.3.5.
The Regen-on/ Regen-off voltages should be set in accordance with the DC Bus voltage, Table 5.4 Typical Regeneration
Turn-on & Turn-off Voltage Levels. These parameters are automatically set when the motor parameters are downloaded
to the controller but should be verified to ensure safe operation.
Open “DS2100
→
Drive Setup
→
Regen Resistor
→
Regen Parameters” and ensure that the “Regen-On Voltage
(V)” and “Regen-Off Voltage (V)” are set correctly
Select Write All.
Confirm that values are correct.
Figure 4.8 Regeneration Parameters