Operating instructions

- 5 -
A
B
C
D
E F
G
H
R
J
K
L
MN
P
U T
S
NC
Alarm Common
Alarm In 3
Alarm In 2
Alarm In 1
RXB
TXB
TXA
Heater /Blower
Heater /Blower
Camera Power
Camera Power
Shield
Video
NC
RXA
NC
INSTALLING THE PAN/TILT
1. Slide the pan/tilt back into place. All of the electrical connections are made by the
edge connector and will be engaged at that point.
2. Place the pan/tilt inside the housing so that the alignment pins are facing the housing
PC board. The two vertical anges on the pan/tilt quick release plate should slide in
between the two vertical anges on the housing plate. There are also notches on the back
side of the quick release plate that align with support tabs on the housing plate (Figure 8).
Figure 8
3. With the two vertical anges lined up and the quick release notches inserted through
the support tabs, slide the pan/tilt side ways, towards the housing PC board. There are
two alignment pins on the front of the quick release plate that will engage with holes on
the housing bracket. The pan/tilt should be pushed side-ways until the panel fastener
aligns with the mating insert in the housing plate. Be gentle with the pan/tilt because
the wiring connections are being made as the pan/tilt is being slid sideways (Figure 9).
Front View Side View
Edge
Connector
Figure 10
Panel
Fastener
4. Tighten the panel fastener with a long Phillips screwdriver (Figure 10).
Figure 9
5. Reattach the bullet-resistant liner. Make sure that the viewing slot is in front of the
ballistic window. Each liner arm has an alignment pin that mates with a hole on the
ballistic. When both pins are aligned with their appropriate alignment hole, the (4) Phillips
head captive screws will align with inserts on the liner arms. Tighten the (4) screws to
secure the liner.
A
B
C
D
E F
G
H
R
J
K
L
MN
P
U T
S
NC
Alarm Common
Alarm In 3
Alarm In 2
Alarm In 1
NC
NC
White/Green
Heater /Blower
Heater /Blower
Camera Power
Camera Power
Orange
White/Orange
Green
GND
NC
Wiring Chart Non-Pressurized Receiver Version
A. Heater
1) Red - Heater 1
2) N/C
3) Red - Heater
B. Camera Power
1) Black - V2
2) Orange - V1
C. RJ45
Wiring Pressurized Receiver Version
The following chart is provided as a general guide for the input power for heater,blower
and camera, between the housing and power supply.
Figure 7
Figure 5
Wire Gauge
VA 22 20 18 16 14 12
70 25ft 40 ft 64 ft 100 ft 162 ft 260 ft
7 m 14 m 20 m 30 m 50 m 80 m
A
B
C
CAUTION: Using smaller than recommended cable sizes can result in poor performance
and damage to the heater and camera.
Figure 7A
Wiring Pressurized Network Version