Operating instructions
Address SW1 SW2 SW3 SW4 SW5 SW6 Address SW1 SW2 SW3 SW4 SW5 SW6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
O On On On On On
On O On On On On
O O On On On On
On On O On On On
O On O On On On
On O O On On On
O O O On On On
On On On O On On
O On On O On On
On O On O On On
O O On O On On
On On O O On On
O On O O On On
On O O O On On
O O O O On On
On On On On O On
O On On On O On
On O On On O On
O O On On O On
On On O On O On
O On O On O On
On O O On O On
O O O On O On
On On On O O On
O On On O O On
On O On O O On
O O On O O On
On On O O O On
O On O O O On
On O O O O On
O O O O O On
CHANGING SETTINGS FOR RECEIVER / DRIVER UNITS
DIPSWITCHES
The dipswitches serve a dual purpose. First, they control the address of the pan/tilt when operated via RS485. Second, they control the alarm and display
functions for the pan/tilt. Address changes are made using the dip switches located on the PC board.
Dipswitches
UNIT ADDRESSES FOR 485 CONTROL
The dipswitches come factory preset with switch 6 in the on position, indicating the address mode. The default address for the pan/tilt on receiver/driver ver-
sions of the DeputyDome™ is preset at the factory as "1." If more than one unit is being used with 485 control it will be necessary to change the address for
each additional unit.
To change the address, power down the unit, remove the pan/tilt from the housing, and set the address using the dipswitch settings shown in Chart 1 in the
next column. Replace the unit and power up.
CHART 1 - RECEIVER/DRIVER PAN/TILT ADDRESSES
19
20
21
22
23
24
25
26
27
28
29
30
31
20
21