User Manual
Table Of Contents
21
SHARED OSCILLATOR PARAMETERS
NOTE: By default, the SEQ 1 and SEQ 2 output jacks will output a control voltage that reflects the current 
Quantize settings. This behavior can be disengaged by pressing and holding the QUANTIZE button until the 
LED flashes, at which point the Oscillators will continue to respect the current Quantize settings, while the 
SEQ 1 and SEQ 2 output jacks will remain unquantized at the patchbay.
QUANTIZE
There are four quantized settings. Pressing the QUANTIZE button will cycle 
through the available settings, with an LED indicating the current selection. 
With all LEDs o, no Quantization value is selected, and the Quantize 
function is o.
12-ET: This option selects a Chromatic (12-step) scale using Equal Temperament 
(ET), which is the basis for Western keyboard music.
8-ET: This option selects a Diatonic (8-step) scale using Equal Temperament (ET).
12-JI: This quantize option uses a Chromatic (12-step) scale using Just 
Intonation (JI).
8-JI: This quantize option uses a Diatonic (8-step) scale using Just Intonation (JI).
THE MIXER
The mixer sets the 
individual levels of all six 
Subharmonicon sound 
sources. The combined 
signal exits the mixer and 
enters the filter section.
NOTE: The mixer can be pushed 
into a warm distortion by 
setting the sound sources near 
their maximum levels. Setting 
the mixer to moderate levels 
will produce a cleaner sound.
VCO 1 LEVEL
This knob sets the level of the VCO 1 signal. Rotating this knob clockwise 
will raise the level; rotating this knob counter-clockwise will lower the level.
THE OSCILLATORS (Continued)
Quantizing focuses the continuous sweep of an oscillator into stepped voltages that, in the ca se
of Subharmonicon , g enerate either a 12-ton e or 8-tone division of the octave (with just or equal
temperaments). Learn more about tuning systems and temperament on page 17. When the Qu antize 
function is engaged, rotating the VCO 1 FREQ knob or the VCO 2 FREQ knob wil l select steps of the 
scale, as defined by the current Quantize setting. The Quantize function is shared by both oscillators; 
it cannot be set individ ually.