User Manual
  Page 60                    
  LP Stage II User’s Manual - Appendices                    
  Page 61 
  LP Stage II User’s Manual - Appendices
Appendix D - The Calibration Preset
SECTION
PARAMETER VALUE
 Modulation
LFO RATE 0
AMOUNT 0
SOURCE SQUARE
DESTINATION WAVE
Oscillators
OSC 1 OCTAVE 16’
WAVE 2048
OSC 1 LEVEL 4095
GLIDE RATE 1726
1-2 SYNC OFF
OCTAVE 16’
OSC 2 FREQ 2048
WAVE 2048
OSC 2 LEVEL 0
Filter
CUTOFF 4095
RESONANCE 0
KB AMOUNT 2701
EG AMOUNT 2048
OVERLOAD 0
Envelope Generator
ATTACK 0
DECAY 0
SUSTAIN 2048
RELEASE 0
ATTACK 0
DECAY 0
SUSTAIN 4095
RELEASE 0
The LP has a specic Calibration Preset that is stored in a non-volatile memory location labeled ‘CA’ (this 
preset location appears after preset 99). The Calibration Preset is a single-oscillator squarewave tone that 
plays Oscillator 1 at full level. This preset is used primarily for the LP’S AutoTune function, but it can also be 
used for tuning the LP with an external tuner. Since the CA preset can be modied like any other preset, it’s 
also useful as a default starting point for preset development. Note that the Calibration Preset cannot be 
saved to the CA memory location, but it can be saved to any other preset location (00-99).
The tables below list the default values of the Calibration Preset (bold text is used to indicate Precision 
Mode values).
SECTION
PARAMETER VALUE
Advanced Preset 
Parameters
FILTER POLES 4
EGR RELEASE ON
GATE LEGATO ON
FILTER SENSITIVITY 0
MOD SOURCE 5 FILT
MOD SOURCE 6 OSC2
PB UP/DN +2 / -2
MOD DEST2 OFF