CALIBRATION (con’t)
NOTE CALIBRATION:
This calibration option allows you to select Note calibration. This 
calibrates individual notes exactly for each oscillator and octave setting. 
Press ENTER to access the Note calibration menu.
The Note calibration menu will be displayed, allowing you to set the 
calibration range. The default note range is MIDI notes 12 - 116. For 
every one of these notes, the pitches are calibrated at each of the 
octave settings, from 16’ to 2’. To change the range, use the CURSOR 
button to move to the start or end eld, and use the VALUE knob to 
select the MIDI note value. Then press ENTER.
Note: A full Note calibration using the default range (12 - 116) can take about two hours 
to complete. By specifying a narrower range of notes (for example, just the range of the LP 
keyboard without octave transpose [48-84], or with octave transpose [24-108]), you can 
shorten the calibration time.
You will be asked if you wish to proceed. Use the VALUE knob to se-
lect YES or NO. If you are uncertain or if you change your mind about 
performing this calibration, select NO and press ENTER. You will be 
returned to the System Utilities Calibration menu. Otherwise, select 
YES and press ENTER. 
Calibration will begin, and the display will appear as shown. The values 
displayed are the MIDI note number being calibrated, the calibration 
value (this is the value stored in the LP’s EEPROM), and the actual 
measured note in MIDI Note Number Cents (in the example shown 
here, ‘32.01’ indicates MIDI note 32 and the actual measured note is 
01 cents sharp). Note calibration will proceed through the specied 
range of notes, tuning each note individually, rst for oscillator 1 and 
then oscillator 2. 
When Note calibration is complete, the message ‘SUCCESSFUL’ will 
appear on the display and the new calibration values will be stored in 
the LP’s EEPROM. To exit the calibration, press ENTER to return to 
the System Utilities Calibration menu or press MASTER to exit the 
calibration and return to the highest level of the System Utilities menu.
Note: You can exit out of Note calibration at any time by pressing the MASTER button. 
Only those notes that have been calibrated up to that point will be saved. The remaining 
notes will revert to their previous calibration values. Interrupting the Note Calibration 
operation in this manner may result in inaccurate tuning.