greaterthanthevaluesspecifiedonthedatasheetorfluctuatingheadingperformancemayindicatemagneticfield
disturb
ancesneartheunit.
NOTE:AnacceptablecalibrationwillprovideXandYHardIronOffsetValuesof<0.1andaSoftIronRatio>0.95.If
thisproceduregeneratescalibrationparameterssignificantlyoutsideofthisrange,thesystemwillassertthe
softwareErrorÆdataErrorÆmagAlignOutOfBoundserrorflag.Referto
Chapter11.BuiltInTest(BIT))for
detailsabouterrorflaghandling.
Formoreinformationaboutmagneticfieldsandtheeffectsonreadingsandalignment,refertoChapter4.
MagnetometerCalibrationandAlignmentGuidelines
onpage39.
AlignmentInstructions
Follo structionsusingNAV‐VIEW2.2.wingarethemagnetometeralignmentin
•
AligningInternalMagnetometer,page58
•
AligningExternalMagnetometer,page59
AligningInternalMagnetometer
1. Ensuretheunitisconfiguredtousetheinternal
Advan page56.
magnetometer.Referto
cedon
2. Onthemenubar(see
Figure8),click
ConfigurationandthenselectMagnetometer
Alignment
fromthedropmenu.
60degreeturncanb within
onds,checkAutoTe
3. Ifthe3 ecompleted
120sec
rminate.
4. Under
RotationalAlignment,selecttheStart
buttontobeginthealignment.Followthe
instructionsdisplayedinthescreen.Referto
Figure21.
5. RotatetheGNAV540for380degreesofrotation
oruntilthemessageisdisplayedthatalignment
iscomplete.
Figure21InternalMagnetometerAlignmentDialog
Page58
GNAV540UserManual
7430‐0808‐01Rev.B