Figure 20� Combustible mantles and facings. (Not to scale)
Finishing Around the Fireplace
Non-combustible mantels and mouldings may be safely installed
over the top and on the front of the replace provided that they do
not project beyond shaded area shown in Figure 20�
The face of the replace may be painted to match the room decor,
provided you use a heat-resistant paint� Decorative facing must not
extend past the replace opening at all, because it will interfere with
the access to retainers for removal of glass door
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
are for re hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models
of replaces which are hot, fuel and energy efcient.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above replace may be hot to touch.
We recommend careful consideration be given to the effects of
elevated mantel temperatures which may be in excess of product
design, for example: candles, plastic or pictures� This can cause
melting, deformation, discoloration or premature failure of T�V� and
radio components�
Side wall clearances are 6"� Combustible surrounds may be installed
with 6" clearance to the side of the replace as shown in Figure 21
Figure 21� Combustible surrounds.
12 11
10 9 8 7 6 5 4 3 2 1
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
1
2
3
4
5
6
7
Glass
Combustible Construction
allowed in shaded area
Combustible Construction
allowed in shaded area
First Combustible
Header @ 14 3/4"
Drywall /
Combustible
Facing
Non-combustible
Header
supplied by Montigo
1/8”
1/8”
1 23
4
5
6 78
9
10
11
12
Drywall / Combustible Facing
Non-Combustible Facing
N
on-combustible Heade
r
6”
15½
Drywall Sheetrock
15 1/2” Non-Combustible
Facing Material
R720 & R820 Power Vent Indoor Gas Fireplace
Page 27