Section 3-5: Heat Shields
Installing a Wall Mounted RHS102 Heat shield
The RHS102 Heat shield must be used if vent pipe passes through
a wall or ceiling within 6' of the unit�
To install the RHS102, Slide the Inner Section over the vent pipe
that will connect to the replace. Then fasten the vent pipe to the
back of the replace with a minimum of three sheet metal screws.
From the outside slide the RHS102 outer section on� To complete
the installation fasten the Heat Shield Outer Section & inner section
to the structure� See Figure 14.
Figure 14.
RHS102 Installation. (Install by sliding over vent pipe
where it passes through the combustible construction).
Outer Shield 11 1/2”
½ ” Min. Both sides Typical
½” Min
.
½” Min
.
Combustible Framing
Inner Shield 11 1/3”
R720 & R820 Power Vent Indoor Gas Fireplace
Page 20
XG0772 - 100614
Installation