Installation
Section 3-1-2: Converting the Pressure Sensing
Tube and Air Bafe
When the R720* / R820* is converted from Top Vent to Rear Vent,
the pressure sensing tube must be removed and replaced with
supplied Rear Vent pressure sensing tube and air bafe must be
relocated as described below
1. Remove two screws from the air bafe installed over the Top
Vent from inside the rebox. Once air bafe is removed, replace
the two screws back into the same position�
Note: Not all models are equipped with an air bafe. Only convert
if available�
2� Remove Top Vent pressure sensing tube by loosening the ��
compression nut with a 1/2" wrench.
3� Position the supplied Rear Vent pressure sensing tube as
4. Install air bafe over Rear Vent from inside the rebox with two
screws provided at the Rear Vent�
shown in Figure 9a� Hand tighten the compression nut by
hand and then a half-turn with a wrench�