Specifications
. Straight Horizontal, Top or Rear Vent, Wall mounted .............
power vent.
Multi-Elbow, Top or Rear Vent, Wall mounted power vent.
Page 19
XG0771 - 040513
This section applies to installations where the shortest possible vent
run is through the wall. Refer to Appendix A - Power Vent locations,
to ensure the planned Power vent location is acceptable. Refer to
the table below for vent run requirements.
Section 3-3: Installing a Wall Mounted Vent System
Vent Conguration Refer to Figure
Maximum Vent Run
(Horizontal + Vertical)
Maximum Elbows†
Straight Horizontal Top or Rear Vent Figure 12
100 Feet
Six 90°
or
equivalent †
Multi-Elbow Top or Rear Vent Figure 12a
Multi-Elbow with 6' downward vent
run Top or Rear Vent
Figure 12b
70 Feet**
† One 90° elbow is equal to two 45° elbows.
** For every additional 1 foot downward vent run subtract 10 feet from the maximum vent run.