Owner`s manual

Page 12
R520-ST & R620-ST Power Vent Indoor Gas Fireplace
Part No. XG0773 - 032211
Installation
Figure 4g. (Installation of Power Vent Module)
Install Power Vent Module
with Power / Communication
Harness
Vertical Roof Top
Power Vent
Vertical Roof Top
Power Vent Rough-in
Kit
Step 5.
Install the Power Vent, Roof-top Stainless steel cover over the
Installed Rough-in Kit. (You can see the Electrical harness con-
nector in the top right corner).
Figure 4e. Figure 4f.
Step 6.
Install the Power Vent Module Power / communication harness.
Hold the Power Vent in close proximity of the assembled Chase,
(with stainless steel cover attached) and plug in the Power Vent
communication / Power Cord. (Note the direction and orienta-
tion of the plug socket). (See Figure 4e & Figure 4f)
Electrical Harness
from Power Vent
Step 7.
Install the Power Vent Module. Place the Power Vent Module
over the stainless steel cover ange and vent pipe, aligning the
Power Vent into nal position. Ensure the Harness is placed
down in the Rough-in box when placing the Power Vent Module
into place. The Power Vent Module will sit ush with the stainless
steel cover if installed correctly.
Figure 4h. (Installed Power Vent Module)
Step 8.
Install (3) three stainless steel fasteners around Power Vent
Module @120 degrees (penetrating through the inner stainless
steel vent cover)
Stainless Steel
Fasteners
CAUTION!
Vent terminations can be very hot. The termination is to be
installed higher than 7 feet above a public walkway.
Do not obstruct, or attempt to conceal, the vent termination.
These actions will affect the operation of the replace, and may be
hazardous.
In heavy snow areas, take extra care to prevent snow buildup
from obstructing the vent termination.