Owner`s manual
Page 12
R520-ST & R620-ST Power Vent Indoor Gas Fireplace
Part No. XG0773 - 032211
Installation
Figure 4g. (Installation of Power Vent Module)
Install Power Vent Module
with Power / Communication
Harness
Vertical Roof Top
Power Vent
Vertical Roof Top
Power Vent Rough-in
Kit
Step 5.
Install the Power Vent, Roof-top Stainless steel cover over the
Installed Rough-in Kit. (You can see the Electrical harness con-
nector in the top right corner).
Figure 4e. Figure 4f.
Step 6.
Install the Power Vent Module Power / communication harness.
Hold the Power Vent in close proximity of the assembled Chase,
(with stainless steel cover attached) and plug in the Power Vent
communication / Power Cord. (Note the direction and orienta-
tion of the plug socket). (See Figure 4e & Figure 4f)
Electrical Harness
from Power Vent
Step 7.
Install the Power Vent Module. Place the Power Vent Module
over the stainless steel cover ange and vent pipe, aligning the
Power Vent into nal position. Ensure the Harness is placed
down in the Rough-in box when placing the Power Vent Module
into place. The Power Vent Module will sit ush with the stainless
steel cover if installed correctly.
Figure 4h. (Installed Power Vent Module)
Step 8.
Install (3) three stainless steel fasteners around Power Vent
Module @120 degrees (penetrating through the inner stainless
steel vent cover)
Stainless Steel
Fasteners
CAUTION!
Vent terminations can be very hot. The termination is to be
installed higher than 7 feet above a public walkway.
Do not obstruct, or attempt to conceal, the vent termination.
These actions will affect the operation of the replace, and may be
hazardous.
In heavy snow areas, take extra care to prevent snow buildup
from obstructing the vent termination.