Specifications
XG0201 Rev. 02 03/2001
Page 10
M38DV-ST / ME38DV-ST Direct Vented Fireplace
Installation
Wiring
Figure 16b. Wiring schematic for optional fans.
Gas Control and Pilot Wiring
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Fuse
Limit
Switch
Wall
Switch
Fan Plug
Receptacle
Junction Box
Junction Box Cover
White
Black
Green
40 VA
Transformer
115VAC
24VAC
Grnd Screw
Figure 15. Wiring for the M38DV-ST / ME38DV-ST-I with Honeywell
gas control and pilot.
Optional Fans
The M38DV-ST / ME38DV-ST may be equipped with 4 optional
fans for circulating heat into the living space. Installations in
Canada which employ the fan kit, must be in accordance with CSA
C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA which employ the fan kit, must be in
accordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70-1987.
Figure 16a. Wiring for optional fans.
NOTE: If any of the original wire supplied with the
appliance is replaced, it must be replaced with the
same type, or its equivalent.
M38DV-ST /
ME38DV-ST-I
115/1/60 Supply
G L1 L2
Fan Switch
Optional Fan Motors
G
L1-WH
L2-BLK
Quick Connect
plug to motor
Fan Switch
Optional Fan Motors
Figure 17b. Completed Installation.
Figure 17a. Log Installation.
Installing the Logs and Embers
Bottom Logs
The M38DV-ST / ME38DV-ST is supplied with five (5) fibre logs. The
two large bottom logs (logs "A" and "B") are mounted on the burner
grate by placing them into the slots.
Top Logs
Place logs "C" and "D" into their mating positions on the large logs as
shown in Figure 16a below. Log "E" is mounted on top of logs "C" and
"D" as shown in Figure 17b.
WARNING:WARNING:
WARNING:WARNING:
WARNING: If logs are not placed properly, excessive
sooting will result.