Specifications
15. Set the High-Low Regulator to desired setting:
Turn fully counterclockwise for High and fully
clockwise for Low. If using a Thermostat, keep
on High setting.
NOTE: An odor, resulting from the initial heating
of new materials in your heater, is not unusual
during the rst re, and in most cases will disap-
pear after an hour or two.
1. If using optional thermostat, set thermostat to
the lowest position.
2. Turn off the electric power to the blower.
3. Turn the ON-OFF switch on the upper right
rear of the stove to the OFF position.
4. Push in the gas control knob slightly and turn it
clockwise to “OFF.”
NOTE: The knob cannot be turned from “PILOT”
to “OFF” unless it is pushed in slightly. Do not
force it.
The ame height adjuster can be accessed by
opening the right side panel. Turn the adjuster clock-
wise to increase ame height and counterclockwise
to decrease. See above left. Adjusting the ames too
high will cause them to have black tips and cause
sooting. Sooting can cause the glass to get dirty.
Check ame height after ve to ten minutes and
readjust if necessary.
If pilot ames are less than shown at left, use
pilot adjuster shown below, to increase ames.
Flame Height
Adjuster
Normal Flame pattern. Note: Flames will vary in height
and position depending on the placement and the amount of
ember wool.
Warning: The unit and
adjuster may be hot.
Wear gloves and arm
protection if making
adjustments while in
operation.
Pilot Adjuster