Tested to ANSI Z21.88-2002, CSA 2.33-M02, and CAN/CGA 2.17-M91.
NATURAL GAS PROPANE
Input Rating (Btu/hr) (0-4500 ft) (0-1375 m) 40,000 40,000
Min. Input Rating (Btu/hr) (0-4500 ft) (0-1375 m) 27,000 28,000
Injectors (DMS) (front/middle/rear) (0-4500 ft) (0-1375 m) 45/56/39 56/71/53
Manifold Pressure (in w.c./kPa) 3.5/0.87 10.0/2.49
Minimum Manifold Pressure (in w.c./kPa) 1.7/0.42 5.9/1.47
Minimum Inlet Pressure (in w.c./kPa) 5.0/1.25 11.0/2.74
Maximum Output (Btu/hr) (0-4500 ft) (0-1375 m) 31,200 32,100
AFUE (seasonal efciency; minimum venting) 71.6 % 73.8 %
Steady State Efciency (max. input, blower on High) 80.2 % 83.3 %
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
Unit to left sidewall 9 in. (230 mm)
Unit to right sidewall 9 in. (230 mm)
Unit corner to walls 4 in. (100 mm)
Unit to backwall 3 in. (75 mm)
(measured from rear of stove to wall)
Unit to alcove ceiling 18 in. (460 mm)
Maximum alcove depth 14 in. (460 mm)
Electrical Rating: 120 Volts 60 Hz Less than 1 Amp
Stove weight: 237 lbs.