Specifications

G0204
Page 2
Panorama Direct Vented Fireplace
Introduction
The 38 Series Direct Vent - Panorama is a multi-sided Gas Fireplace
with an adjustable center burner and air-circulating fans. It is available in
two models:
n Model M38DV-PRC (continuous pilot)
n Model M38DV-PRC-I (intermittent pilot)
This manual covers both models and unless otherwise specified, the
designation M38DV-PRC refers to both models. Sections which are
specific to a particular model are marked with a symbol,
plus the appropriate model number.
The M38DV-PRC is rated for:
n Natural Gas at 30,000 BTU/H (8.78 Kilowatts) max. input, and
23,400 BTU/H (6.86 Kilowatts) min. input
n Propane at 28,000 BTU/H (8.20 Kilowatts) max. input, and
21,800 BTU/H (6.40 Kilowatts) min. input
The Montigo warranty will be voided by, and Montigo disclaims any
responsibility for, the following actions:
n Modification of the fireplace and/or components including Direct-
Vent assembly or glass doors.
n Use of any component part not manufactured or approved by
Montigo in combination with this Montigo fireplace system.
n Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation requirements
for factory-built gas fireplaces. Installation & repairs should be done by
a qualified contractor.
Installations in Canada must conform to the current CAN/CGA B-
149.1 and .2 Gas Installation Code and local regulations. This
fireplace's fans must be electrically grounded in accordance with CSA
C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA must conform to local codes, or in the
absense of local codes to the National Fuel Gas Code, ANSI Z223.1-
1988. The fans must be grounded in accordance with local codes or, in
the absence of local codes, with the National Electrical Code, ANSI/
NFPA 70-1987.
Table Of Contents
Introduction.............................................................................2
Installation........................................................................3 - 12
Installing the Fireplace Shell...........................................3
Installing the Gasline ......................................................4
The Remote Switch ....................................................... 4
Direct Vent Installation ...................................................4
General Requirements ......................................4
Terminations .....................................................5
Horizontal Venting Runs....................................6
Vertical Venting Runs ........................................8
Construction around the fireplace
Facing ...........................................................10
Mantels and Surrounds ...................................10
Installing the Logset .....................................................10
Pilot Burner Adjustment ...............................................11
Gas Control Valve........................................................11
Fans ...........................................................11
Removing and Installing the Insert ...............................12
Removing and Installing the Door ................................ 12
Operation ..........................................................................13-14
Model M38DV-PRC ..................................................... 13
Model M38DV-PRC-I .................................................. 14
Maintenance .......................................................................... 15
Warranty.................................................................................16
CAUTIONS
Due to its high operating temperatures, the appliance
should be located out of traffic & away from furniture and
draperies.
Children and adults should be alerted to the hazards
of the high surface temperature, which could cause
burns or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other flammable materials should not be
placed on or near the appliance.