Questions? Email us at fireplaces@montigo.com or visit our website at www.montigo.com. Installation Operation & Maintenance M38DV-PRC Panorama Direct-Vented Gas Fireplace Warning: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
Panorama Direct Vented Fireplace Table Of Contents Introduction ............................................................................. 2 Installation ........................................................................ 3 - 12 Installing the Fireplace Shell ........................................... 3 Installing the Gasline ...................................................... 4 The Remote Switch ....................................................... 4 Direct Vent Installation ................
Panorama Direct Vented Fireplace Installation Installing The Fireplace Shell The fireplace may be installed in any location that maintains clearances to air conditioning ducts, electrical wiring and plumbing. Safety, as well as efficiency of operation, must be considered when selecting the fireplace location. Try to select a location that does not interfere with room traffic, has adequate ventilation, and offers an accessible pathway for Direct Vent installation.
Panorama Direct Vented Fireplace Installation Installing The Gas Line Vent Installation The gas line must be installed before finishing the M38DV-PRC fireplace. Natural Gas requires a minimum inlet gas supply pressure of 5.5" W.C. & a manifold pressure of 3.5" W.C. Propane Gas requires a minimum inlet gas supply pressure of 11" W.C. & a manifold pressure of 10" W.C. Provision must also be made for a 1/8" N.P.T.
Panorama Direct Vented Fireplace Installation Vent Terminations Installing Terminations with Built-In Frames 1. Frame the termination opening to 11" x 11". 2. Fasten the termination to the studs using a minimum of 4 screws. 2. Attach to the faceplate of the termination using four sheet metal screws. 11 PTO-3F PTKOG 11 Figure 5d. Installing the heat guard. Venting Runs If your installation requires more than 12" of horizontal venting, some vertical lift is required.
Panorama Direct Vented Fireplace Installation Direct Vent Installation Vent systems that terminate through a wall may comprise up to six different components: A - Termination PTO-3 (3" length) B - Stucco Kits PTO-3F (3" length) MSR (stucco frame) MOSR (stucco can) BSR (brick can) C - Flex sections D - Solid sections E - Extensions F - 90° elbow PFL-1 (12" section) PFL-2 (24" section) PFL-3 (36" section) PFL-4 (48" section) PEXT-1 (12" section) PEXT-2 (24" section) PEXT-3 (36" section) PEXT-4 (48" se
Panorama Direct Vented Fireplace Installation Vertical Vent Installations n Vertical Terminations must be installed: • minimum 2' (two feet) above the highest point where vent passes through the roof. • minimum 6' (six feet) from a mechanical air inlet • minimum 18" (1 1/2 feet) from a parapet wall. n Maximum vent height is 30 feet above fireplace. Note: Flame characteristics will change if the maximum vent height is used.
Panorama Direct Vented Fireplace Installation Finishing Around the Fireplace Combustible mantels and mouldings may be safely installed over the top and on the front of the fireplace provided that they do not project beyond shaded area shown in Figure 13a. Side wall clearances are 0". Combustible surrounds may be installed with 0" clearance to the side of the fireplace as shown in Figure 13b.
Panorama Direct Vented Fireplace Installation Wiring 115/1/60 Supply G L1 L2 M38DV-PRC-I Honeywell (Q3450) Pilot Assembly Fan Switch Pilot Electrical Harness Connector Fan Motors (4) Gas Control and Pilot Wiring Honeywell Gas Control (SV9501M) Figure 15b. Fan wiring schematic.
Panorama Direct Vented Fireplace Installation Operation Installing the Logs and Embers Lighting Instructions Bottom Logs The M38DV-PRC is supplied with five (5) fibre logs. The two large bottom logs (logs "A" and "B") are mounted on the burner grate by placing them into the slots. Top Logs Place logs "C" and "D" into their mating positions on the large logs as shown in Figure 16a below. Log "E" is mounted on top of logs "C" and "D" as shown in Figure 15b.
Panorama Direct Vented Fireplace M38DV-PRC Operation - Model M38DV-PRC with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas.
Panorama Direct Vented Fireplace M38DV-PRC-I Operation - Model M38DV-PRC-I with Honeywell Intermittent Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition system that lights the pilot burner automatically. Do not attempt to light the pilot by hand. B. BEFORE LIGHTING smell all around the appliance area for gas.
Panorama Direct Vented Fireplace Maintenance CAUTION • Fireplace gas control must be in the “OFF” position and pilot and main burners extinguished when cleaning appliance with a vacuum. • Gas Control Valve Secondary Ve n t S a fe ty Limit S w itch T h e rm o co u p le C o n n e ctio n Power G e n e ra to r Glass and logs can get very hot. Handle only when cool. P ilo t A d ju stm e n t S cre w W a ll S w itc h n For Natural Gas this appliance requires a minimum inlet pressure of 5.5" W.C.
Panorama Direct Vented Fireplace Maintenance Troubleshooting M38DV-PRC TroubleshootingM38DV-PRC-I The following is a troubleshooting chart of possible problems: PROBLEM Noisy Pilot Flame Pilot won’t ignite Main burner will not light HONEYWELL SV 9500 /SV9600 Troubleshooting Sequence CORRECTIVE ACTION Locate pilot adjustment screw on the front of the gas control valve. Flame is decreased by turning adjustment screw clockwise. Disconnect remote wires and try to light pilot.
Panorama Direct Vented Fireplace Warranty The Warranty The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner, and a one-year warranty on the pilot burner, gas control valve and fibre logs. Glass, plated/painted finishes, and refractory lining are exempt.
Panorama Direct Vented Fireplace Appendix A - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, or balcony [16 inches (41 cm) minimum] B = clearance to door, or sides and top of window, that may be opened [16 inches (41 cm) minimum for appliances ≤100 000 BTU/H (30kW)] C = clearance to bottom of window that may be opened horizontally [36 inches (92 cm) minimum for appliances ≤100 000 BTU/H (30kW)] M = clearance to mechanical air supply inlet [*6 feet (1.
Panorama Direct Vented Fireplace Notes G0204 Page 17
XG0204 Rev. 00 - 04/2001 Canadian Heating Products Inc. Montigo Del Ray Corp.