Installation Operation & Maintenance M38DV-PFC Peninsula Direct-Vented Gas Fireplace Warning: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. For Your Safety: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
M38DV-PFC Peninsula Gas Fireplace Table Of Contents Introduction................................................................................ 2 Installation...........................................................................3 - 12 Installing the Fireplace Shell........................................... 3 Installing the Gasline....................................................... 4 The Remote Switch......................................................... 4 Direct Vent Installation.............
M38DV-PFC Peninsula Gas Fireplace Installation Installing The Fireplace Shell The fireplace may be installed in any location that is free of air conditioning ducts, electrical wiring and plumbing. Safety, as well as efficiency of operation, must be considered when selecting the fireplace location. Try to select a location that does not interfere with room traffic, has adequate ventilation, and offers an accessible pathway for Direct Vent installation.
M38DV-PFC Peninsula Gas Fireplace Installation Installing The Gas Line Vent Installation The gas line must be installed before finishing the M38DV-PFC fireplace. Natural Gas requires a minimum inlet gas supply pressure of 5.5" W.C. & a manifold pressure of 3.5" W.C. Propane Gas requires a minimum inlet gas supply pressure of 11" W.C. & a manifold pressure of 10" W.C. Provision must also be made for a 1/8" N.P.T.
M38DV-PFC Peninsula Gas Fireplace Installation Venting Runs Installing Terminations with MSR Frames 1. Frame the termination opening to 12" x 12". 2. Fasten the termination to the studs using a minimum of 4 screws. 12 MSR If your installation requires more than 12" of horizontal venting, some vertical lift is required. Use the vent graph below to determine an acceptable vent run. Unacceptable venting can affect the fireplace's combustion.
M38DV-PFC Peninsula Gas Fireplace Installation Direct Vent Installation Vent systems that terminate through a wall may comprise up to six different components: A - Termination 12" max.
M38DV-PFC Peninsula Gas Fireplace Installation Vertical Vent Installations Vertical Terminations must be installed: • minimum 2' (two feet) above the highest point where vent passes through the roof. • minimum 6' (six feet) from a mechanical air inlet • minimum 3' (three feet) from a parapet wall. Maximum vent height is 30 feet above fireplace. Note: Flame characteristics will change if the maximum vent height is used.
M38DV-PFC Peninsula Gas Fireplace Installation Finishing Around the Fireplace Combustible mantels and mouldings may be safely installed over the top and on the front of the fireplace provided that they do not project beyond shaded area shown in Figure 13a. Side wall clearances are 0". Combustible surrounds may be installed with 0" clearance to the side of the fireplace as shown in Figure 13b.
M38DV-PFC Peninsula Gas Fireplace Installation Wiring 115/1/60 Supply G L1 L2 M38DV-PFC-I Honeywell (Q3450) Pilot Assembly Fan Switch Pilot Electrical Harness Connector Fan Motors (3) Gas Control and Pilot Wiring Honeywell Gas Control (SV9501M) Figure 15b. Fan wiring schematic.
M38DV-PFC Peninsula Gas Fireplace Installation Removing and Installing the Inner Doors Operation Lighting Instructions See Pages 11-12. Door Removal The inner (combustion) doors are located behind the outer decorative doors. To remove the inner doors, simply unscrew the nine (9) machine screws on the top, bottom and side of the door. (See figure 17). Door Installation To attach the inner doors, align the door with the screw holes and re-fasten with all nine machine screws.
M38DV-PFC Peninsula Gas Fireplace M38DV-PFC Operation - Model M38DV-PFC with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas.
M38DV-PFC Peninsula Gas Fireplace M38DV-PFC-I Operation - Model M38DV-PFC-I with Honeywell Intermittent Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition system that lights the pilot burner automatically. Do not attempt to light the pilot by hand. B. BEFORE LIGHTING smell all around the appliance area for gas.
M38DV-PFC Peninsula Gas Fireplace Maintenance • • CAUTION Fireplace gas control must be in the “OFF” position and pilot and main burners extinguished when cleaning appliance with a vacuum. Gas Control Valve Secondary Limit Vent Safety Switch Thermocouple Connection Power Generator Glass and logs can get very hot. Handle only when cool. Pilot Adjustment Screw Wall Switch For Natural Gas this appliance requires a minimum inlet pressure of 5.5" W.C. and a manifold pressure of 3.5" W.C.
M38DV-PFC Peninsula Gas Fireplace Maintenance Troubleshooting TroubleshootingM38DV-PFC-I M38DV-PFC The following is a troubleshooting chart of possible problems: PROBLEM Noisy Pilot Flame Pilot won’t ignite Main burner will not light HONEYWELL SV 9500 /SV9600 Troubleshooting Sequence CORRECTIVE ACTION Locate pilot adjustment screw on the front of the gas control valve. Flame is decreased by turning adjustment screw clockwise. Disconnect remote wires and try to light pilot.
M38DV-PFC Peninsula Gas Fireplace Warranty The Warranty The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner, and a one-year warranty on the gas control valve, pilot burner and fibre logs. Glass, plated/painted finishes, and refractory lining are exempt.
M38DV-PFC Peninsula Gas Fireplace Appendix A - Spare Parts 1 Model M38DV-PFC 2 PSE 3 4 5 6 5/16 A lum . Tub ing 7 Model M38DVPFC-I 8 5/16 A lum . Tub ing 9 1. 2. 3. 4. 5. Fan Motor (MBL-1) Power Cord (PPCH-4) Stucco Frame (MSR) Stucco Frame (MOSR) Brick Frame (BSR) Page 16 6. 7. 8. 9.
M38DV-PFC Peninsula Gas Fireplace Appendix B - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, or balcony [16 inches (41 cm) minimum] B = clearance to door, or sides and top of window, that may be opened [16 inches (41 cm) minimum for appliances ≤100 000 BTU/H (30kW)] C = clearance to bottom of window that may be opened horizontally [36 inches (92 cm) minimum for appliances ≤100 000 BTU/H (30kW)] D = no clearance to permanently closed window when installed w