Specifications
XG0400 05/00
Page 2
M38BV-ST B-Vented Fireplace
Introduction
The M38BV-ST is a See-Thru Gas Fireplace with glass doors on two
sides and an adjustable center burner. This fireplace is for use with
standard 4" B-Vent It is available in two models:
n Model M38BV-ST (continuous pilot)
n Model M38BV-ST-I (intermittent pilot)
This manual covers both models and unless otherwise specified, the
designation M38BV-ST refers to both models. Sections which are
specific to a particular model are marked with a symbol,
plus the appropriate model number.
The M38BV-ST is rated for:
n Natural Gas at 32,000 BTU/H (9.4 Kilowatts) Max. Input, and
11,000 BTU/H (3.2 Kilowatts) Min. Input when the middle burner
is turned off
n Propane at 32,000 BTU/H (9.4 Kilowatts) Max. Input, and
11,000 BTU/H (3.2 Kilowatts) Min. Input when the middle burner
is turned off
The Montigo warranty will be voided by, and Montigo disclaims any
responsibility for, the following actions:
n Modification of the fireplace and/or components including glass
doors.
n Use of any component part not manufactured or approved by
Montigo in combination with this Montigo fireplace system.
n Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation
requirements for factory-built gas fireplaces. Installation & repairs
should be done by a qualified contractor.
Installations in Canada must conform to the current CAN/CGA B-
149.1 and .2 Gas Installation Code and local regulations. This unit
employs fans and must be electrically grounded in accordance with
CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA must conform to the National Fuel Gas
Code, ANSI Z223.1-1988. This unit employs fans and must be
grounded in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70-1987.
Table Of Contents
Introduction ............................................................................ 2
Installation
Installing the Fireplace Shell ....................................... 3
Installing the Gasline ................................................... 4
The Remote Switch .....................................................4
Vent Requirements ......................................................4
Finishing around the fireplace
Facing ............................................................. 5
Mantels and Surrounds ................................... 5
Installing the Logset..................................................... 6
Wiring ......................................................................... 6
Removing and Installing the Door ............................... 7
Operation
Adjusting the Center Burner ........................................ 7
Lighting Instructions - Model M38BV-ST .................... 8
Lighting Instructions - Model M38BV-ST-I .................. 9
Maintenance
Cleaning .....................................................................10
Gas Control Valve ...................................................... 10
Pilot Burner Adjustment .............................................10
Troubleshooting .........................................................11
Warranty ................................................................................ 12
Appendices
A - Spare Parts ..........................................................13
CAUTIONS
Due to its high operating temperatures, the appliance
should be located out of traffic & away from furniture and
draperies.
• Children and adults should be alerted to the hazards
of the high surface temperature, which could cause
burns or clothing ignition.
• Young children should be carefully supervised when
they are in the same room as the appliance.
• Clothing or other flammable materials should not be
placed on or near the appliance.