Owner`s manual

Page 7
L52DF Flush Indoor Gas Fireplace
Part No. XG0185 - 092909
f i r e f e a t u r e
Figure 6c. Installing the Nailing Flange Extension.
Installation
Converting to Top Vent/ Rear Vent
L52DF Top Vent
Use the following instructions to convert an L52DF Top Vent. For Top
Vent use:
1. Installthe5"inneruecapontherearueoutletandsecurethe
capinplacewithvescrews,asshowningure7a.
2. Installthe8"outeruecapontherearueoutlet,andsecureit
withvescrews,asshowningure7a.
3. Installtheuegasketmaterialanduecoverplateontherearvent
outlet . Fasten the plate with four screws, as illustrated below.
4. Installthe5"inneruecollarandthe8"outeruecollarinplace
on the top vent outlet using 5 screws, as illustrated below.
L52DF Rear Vent
Use the following instructions to convert an L52DF Only for Rear Vent use:
1. Installthe5"inneruecaponthetopueoutletandsecurethe
capinplacewithvescrews,asshowningure8a.
2. Installthe8"outeruecaponthetopueoutlet,andsecureit
withvescrews,asshowningure8a.
3. Installtheuegasketmaterialanduecoverplateonthetop
vent outlet. Fasten the plate with four screws, as illustrated in
gure8b.
4. Installthe5"inneruecollarandthe8"outeruecollarinplace
on the rear vent outlet using 5 screws, as illustrated below.
5” Inner Flue Cap
8” Outer Flue Cap
Flue Gasket
Flue Cover Plate
8” Outer Flue Collar
5” Inner Flue Collar
5” Inner Flue Collar
8” Outer Flue Collar
Flue Gasket
Flue Cover Plate
5” Inner ue CapFl
Fl8” Outer ue Cap
Figure 7a. Flue cap installation, Top Vented L52DF replace.
Figure 7b. Flue collar installation, Top Vented L52DF replace.
Figure 8a. Flue cap installation, Rear Vented L52DF replace.
Figure 8b. Flue collar installation, Rear Vented L52DF replace.
Top Vent Venting Runs
For the L52DF Top Vent, there are two types of installations: A) Through-
The-Wall Installations and B) Vertical (Through-The-Roof) Installations.
A) Through-The-Wall Installations
Before you install any venting, you must determine whether the venting
runwillbeacceptable.Unacceptableventingcanaffectthereplace's
combustion.
The Venting Graph
Measuretheverticalheightfromthereplacehearthtothecentreofthe
terminationandthehorizontalrunfromthefromthereplaceue
Installing the Nailing
Flange Extension
Oncethereplaceisplacedintotheroughframedopening,andthe
supplied steel lintel is in place, (Part No. L42087) (see Figure 2),
the supplied nailing extension must be placed along the top edge of
thereplaceandsecurelyfastenedinplacetothemetallintel,and
combustiblewoodframing.Note:Thenailingangeextensioncanbe
substituted with a piece of NON-Combustible material of the same
size and thermal characteristics, ie: cement board or equivilent.