Owner`s manual

Page 14
L52DF Flush Indoor Gas Fireplace
Part No. XG0185 - 092109
f i r e f e a t u r e
Installation
Surround Heat Shield
IncludedwiththeL52DFGasreplace,isaheatshieldfabricatedfrom
galvanized steel. The kit comes with three (3) pieces as shown below.
This shield is to protect all adjacent combustible mantels and mouldings
fromexcessiveheatradiatedbythecabinetofthereplace.Thisshield
must be installed as shown in Figure 24a.
1).Topshieldfastenedasshown.Wideangefaceup,shallowange
towardinsideofroom,nailedorscrewedushwithframing.
2).Sideshield'sfastenedasshown.Wideangesfaceout,shallowange
towardinsideofroom,nailedorscrewedushwithframing.
Painting:
Special care is recommended by the Master Painters and Decorators
Association,whenpaintingthereplacesurrounds,toselectandapply
a quality Alkyd sealer prior to the applying of latex paints. This is to
prevent leaching of water from evaporation and causing a brownish
staining effect to paint over coats.
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
areforrehazardpreventiontocombustiblematerials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
replaceswhicharehot,fuelandenergyefcient.
Please be aware; temperatures over the mantel will rise above normal
roomtemperatureandwallsabovereplacemaybehottotouch.
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
areforrehazardpreventiontocombustiblematerials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
replaceswhicharehot,fuelandenergyefcient.
Please be aware; temperatures over the mantel will rise above normal
Figure 24a. Combustible surround Shield, (three (3-pcs).
Fasteners
3-Per Shield
Framing
1/2
Side shield
Side shield
Top shield
Framing
1/2
Fasteners
3-Per Shield
4
Figure 25. Combustible surrounds.
Non-Combustible
Fa
cing Material
Header
Drywall/
Sheetrock
6”
3”
Wiring
Gas Control and Pilot Wiring
L52DF-I
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Junction Box
115VAC
24VAC
40 VA
Transformer
Black
White
Green
Gnd Screw
Wall Switch
Fan Plug
Receptacle
Figure 26. Wiring for the L52DF-I with Honeywell gas control and pilot.
WARNING!
Use Montigo Part No. #HSIT07 Water-tight electrical box, or
equivilent equipment. Ensure the box is installed in a dry location
and avoid any moisture. Figure 26a.
If you install 110V Wire, ensure you use Ground fault breakers.
Also avoid any moisture near or around the 110V Circuit.
L52DF