L42DF Flush Indoor Gas Fireplace
Part No. XG0181 - 081009
f i r e f e a t u r e
Installation
Horizontal Venting
Figure 13. Typical Top Vent installation. The solid sections can be used in
various combinations to obtain the desired vent run. The vent
run must fall within the limits set by the venting graph.
Figure 14. Extended Installation using a combination of solid and ex
venting. Use the vent graph to determine your allowable
run, then select appropriate components.
90° Elbow
PEXT Section
Termination
Example 3:
Rigidsectionsandanelbowusedinconjunctionwith3ft.exsection
(PFL-3)will,whenextendedinavefootchase,allowforamaximum
horizontalrunoftwelveandone-halffeetfromthecentreofthereplace
tooutsidewallandaminimumof7'6"whenretractedinoppositedirection
(see Figure 14 and 15).
"C"exsectionsand"D"rigidsectionsmaybeusedinconjunctionwith
one another to obtain different possible horizontal length installations.
NOTE: Flex section with no vertical rise must not exceed maximum
horizontal length of 3 feet (see Figure 14). Flex runs over 6' feet must
fall within the limits set by the venting graph, and must have a minimum
verticalriseof3"perfootofex.
Figure 15. Retracted Installation using a combination of solid and ex
venting. Use the vent graph to determine your allowable
run, then select appropriate components.
Figure 16. Horizontal ex installation with MIN vertical rise.
45° or less Corner Installation. (Only available using Top Vent.)
Use a PTO-3 termination and an PFL-1 or PFL-2 (12" or 24"
compressed length) and a frame, if appropriate. Flex may be turned to
obtain desired degree of angle required but must not exceed 45°.
Figure 12. Flex installation. (NG Models Only)
RHS8
RHS8
RHS8
3 feet
max