f i r e f e a t u r e
Installation
Figure 24. Combustible mantles and facings.
Horizontal Run (in)
Fasteners
3-Per Shield
Framing
1/2
Side shield
Side shield
Top shield
(L42-DF only)
(L42-DF only)
(L42-DF only)
Painting:
Special care is recommended by the Master Painters and Decorators
Association,whenpaintingthereplacesurrounds,toselectandapply
a quality Alkyd sealer prior to the applying of latex paints. This is to
prevent leaching of water from evaporation and causing a brownish
staining effect to paint over coats.
Figure 24a. Combustible surround Shield, (three (3-pcs).
Surround Heat Shield
Included with the L42DFGasreplace,isaheatshieldfabricatedfrom
galvanized steel. The kit comes with three (3) pieces as shown below.
This shield is to protect all adjacent combustible mantels and mouldings
fromexcessiveheatradiatedbythecabinetofthereplace.Thisshield
must be installed as shown in Figure 24a.
1).Topshieldfastenedasshown.Wideangefaceup,shallowange
towardinsideofroom,nailedorscrewedushwithframing.
2).Sideshield'sfastenedasshown.Wideangesfaceout,shallowange
towardinsideofroom,nailedorscrewedushwithframing.
Figure 25. Combustible surrounds.
Non-Combustible
Fa
cing Material
Header
Drywall/
Sheetrock
6”
3”
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
areforrehazardpreventiontocombustiblematerials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
replaceswhicharehot,fuelandenergyefcient.
Please be aware; temperatures over the mantel will rise above normal
roomtemperatureandwallsabovereplacemaybehottotouch.
Steel Stud construction
allowable within this area
Top of
fireplace
Non-Combustible
Combustible Facing
Material
Facing Material
Combustible
Construction allowed
in shaded area
WARNING!
We recommend careful consideration be given to the effects of
elevated mantel temperatures which may be in excess of product
design, for example: candles, plastic or pictures. This can cause
melting, deformation, discoloration or premature failure of T.V.
and radio components.