Owner`s manual
Page 13
L42DF Flush Indoor Gas Fireplace
Part No. XG0181 - 081009
f i r e f e a t u r e
Reduced Vertical Installation
(Available with Linear LDVPV47 Power Vent
ONLY)
It is possible to reduce vertical vent runs from 5"/8" venting to 4"/7"
venting. Reduced vertical venting may only be used when the Linear
(In-line) Power Vent is required. This is commonly due to longer than
normal vent runs, or unusually long horizontal Vent runs.
Installation
Figure 21. Reducing Vertical Vent from 5/8" to 4/7".
Installing The Horizontal &
Vertical Exterior Power Vent
A Power Vent is required where the Termination is located too far
away from the gas fireplace and/or if the vent run is beyond the scope
of this document, or the specications recommend vent augmenta-
tion. There are four 4/7 Power Vent models available. These Power
Vents are required for Superior venting, safe operation & years of
trouble free operation.
The available Montigo Power Vent models are:
LDVPV47 (Linear, Interior In-line Power Vent, document, XG0700).
EDVPV47 (External Power Vent Module, document, XG0750).
EDVRSPV47 (Exterior Vertical Roof mount 4/7 stainless steel Power
Vent system, document, XG1303)
EDVWSPV47 (Exterior Horizontal Wall mount 4/7 stainless steel Power
Vent system, document, XG1302).
WARNING!
When coveringtheupper metal portion of the replace,upto
6"(as shown, Fig.24 & Fig.25) with a non-combustible material
Please Note: The decorative facing materials may be subject to
temperatures in excess of 250° F. This should be considered
when selecting facing materials.
Fireplace Facing
Whenselectingthenishmaterialforyourreplace,itisimportantto
remember the following: THE OPENING MUST NOT BE OBSTRUCTED
IN ANY WAY - to do so restricts the air supply for the control
compartments and heat exchanger it also prevents access for
servicing controls.
The faceofthereplace may be painted to match theroomdecor,
provided you use a heat-resistant paint. Decorative facing must not
extendpastthereplaceopeningatall,becauseitwillinterferewith
the access to retainers for removal of glass door.
Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed over the
topandonthefrontofthereplaceprovidedthattheydonotproject
beyond shaded area shown in Figure 24.Sidewallclearancesare3".
Combustiblesurroundsmaybeinstalledwith3"clearancetotheside
ofthereplaceasshowninFigure 25.