Owner`s manual
Page 11
L42DF Flush Indoor Gas Fireplace
Part No. XG0181 - 081009
f i r e f e a t u r e
Figure 16. Vertical venting with 1 oset (1 oset= two 90° bends).
Rear Vent Venting Runs
The L42DF Rear Vent has three possible installations which do not
require vertical lift, all of these installations require that you install the
RHS101 heat shield.
Heat Shield
The heat shield (RHS101) must be used on all installations straight
through the wall, at the point where the vent pipe connects to the
termination. With the heat shield, proper vent clearances can be
maintained. The heat shield is not included with the replace.
To install the heat shield, slide one section over the vent pipe on the inside
of the wall opening, with the circular portion inside the wall cavity. Screw
the shield in place over the wall opening. Install the second section on
the outside of the wall opening sliding the circular portion into the wall
opening. Refer to Figure 19.
Figure 19. Heat Shield. Install by sliding over the vent pipe where it
passes through combustible construction.
Installation
Figure 17. Vertical venting with 2 osets (1 oset= two 90° bends).
* Minimum 1-1/2" clearance to combustibles
32’ max
Installation
The following venting components are available for an L42-DF, in a
Rear Vent installation:
5" / 8" Venting
A - Termination
PTO-3(3"Length)
PTO-3F(3"Length)
B - Stucco Kits
MSR (Stucco Frame)
BSR-4(4"BrickFrame)
BSR-6(6"BrickFrame)
MOSR (Stucco Can)
C - Flex Sections
PFL-1(12"Section)
PFL-2(24"Section)
PFL-3(36"Section)
PFL-4(48"Section)
D - Rigid
Sections
PEXT-1(12"m/fSection)
PXT-20(20"section)
PEXT-2(24"m/fSection)
PEXT-3(36"m/fSection)
PEXT-4(48"m/fSection)
E - Elbows
PEL-90MM (m/m 90° Elbow)
PEL-90FF (f/f 90° Elbow)
PEL-90FM (f/m 90° Elbow)
PEL-45FM (f/m 45° Elbow)