L42DF-ST See-thru Indoor Gas Fireplace
Part No. XG0812 - 081009
f i r e f e a t u r e
Reduced Vertical Installation
(Available with Linear LDVPV47 Power Vent
ONLY)
It is possible to reduce vertical vent runs from 5"/8" venting to 4"/7"
venting. Reduced vertical venting may only be used when the Linear
(In-line) Power Vent is required. This is commonly due to longer than
normal vent runs, or unusually long horizontal Vent runs.
Installation
Figure 18. Reducing Vertical Vent from 5/8" to 4/7".
Installing The Horizontal &
Vertical Exterior Power Vent
A Power Vent is required where the Termination is located too far
away from the gas fireplace and/or if the vent run is beyond the
scope of this document, or the specications recommend vent
augmentation. There are four 4/7 Power Vent models available.
These Power Vents are required for Superior venting, safe opera-
tion & years of trouble free operation.
The available Montigo Power Vent models are:
LDVPV47 (Linear, Interior In-line Power Vent, document, XG0700).
EDVPV47 (External Power Vent Module, document, XG0750).
EDVRSPV47 (Exterior Vertical Roof mount 4/7 stainless steel Power
Vent system, document, XG1303)
EDVWSPV47 (Exterior Horizontal Wall mount 4/7 stainless steel
Power Vent system, document, XG1302).
Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed over the
topandonthefrontofthereplaceprovidedthattheydonotproject
beyond shaded area shown in Figure 24.Sidewallclearancesare3".
Combustiblesurroundsmaybeinstalledwith3"clearancetotheside
ofthereplaceasshowninFigure 25.
Fireplace Facing
Whenselectingthenishmaterialforyourreplace,itisimportantto
remember the following: THE DOOR OPENING MUST NOT BE OB-
STRUCTED IN ANY WAY - to do so restricts the air supply for the
control compartments and heat exchanger it also prevents access
for servicing controls.
The faceofthereplace may be painted to match theroomdecor,
provided you use a heat-resistant paint. Decorative facing must not
extendpastthereplaceopeningatall,becauseitwillinterferewith
the access to retainers for removal of glass door.
Horizontal Run (in)
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
areforrehazardpreventiontocombustiblematerials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
replaceswhicharehot,fuelandenergyefcient.
Please be aware; temperatures over the mantel will rise above normal
roomtemperatureandwallsabovereplacemaybehottotouch.
Figure 24. Combustible mantles and facings, (Both Sides Typical).
Non-Combustible
Facing Material
Steel Stud construction
allowable within this area
Top of
fireplace
WARNING!
When coveringtheupper metal portion of the replace,upto
6"(as shown, Fig.24 & Fig.25) with a non-combustible material
Please Note: The decorative facing materials may be subject to
temperatures in excess of 250° F. This should be considered
when selecting facing materials.
We recommend careful consideration be given to the effects of
elevated mantel temperatures which may be in excess of product
design, for example: candles, plastic or pictures. This can cause
melting, deformation, discoloration or premature failure of T.V.
and radio components.