Owner`s manual
L42DF-ST* Indoor Gas Fireplace
XG0182 - 112811
Installation
The L42DF*-ST Direct Vent replace must be installed in accordance
with these Instructions. Carefully read all the Instructions in this manual
rst. Consult the Local Gas Branch to determine the need for a permit
prior to starting the installation. It is the responsibility of the installer to
ensure this replace is installed in compliance with the manufacturers
instructions and all applicable codes.
Determine the desired install location of your replace.
See , Dimensions on and refer to the Framing
for details.
Select the location of your termination and resulting vent run.
.
Should it be impossible to meet the venting requirements laid
out in : Venting, please contact Montigo regarding the
use of a Montigo Power Vent.
Lay out the Vent run; calculating the required elbows and straight
runs of 5"/8" flex or rigid pipe.
Layout Electrical Requirements Refer to Wiring, for
Details.
Refer to Installing the Gas Line, for details on the
gas connection and access.
Refer to local codes and guidelines for installation requirements.
:
• must conform to the current CAN/
CGA B-149.1 and .2 Gas Installation Code and local regulations.
• must conform to local codes, or in
the absence of local codes to the National Fuel Gas Code, ANSI Z223.1
.
•
. This replace must comply with NFPA-54 Chapter 10.
Installation and repairs should be done by an authorized gas fireplace service technician.
The appliance should be inspected before use and at least annually by a professional. More
frequesnt cleaning may be required due to exessive lint from carpeting, bedding material,
ect. It is imperative that control compartments, burners and circulating air passageways of
the fireplace are kept clean.
NOTICE
Due to high operating temperatures, this appliance should be located out of traffic &
away from furniture and draperies.
Children and adults should be alerted to the hazards of the high surface temperature,
which could cause burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the
appliance.
Clothing or other flammable materials should not be placed on or near the appliance.
CAUTION
When this appliance is installed directly on any combustible material other than wood
flooring, it must be installed on a metal or wood panel extending the full width and
depth of the appliance or a fire will occur causing serious injury, property damage or
even death.