Owner`s manual


L42DF* Indoor Gas Fireplace
XG0181 -112811.1
Installation

1” clearance is maintained on sides and bottom of vent runs and 2”
above horizontal vent runs to any combustible material.







      
6”

To avoid elevated mantel temperatures, all gas
replaces are required to have the supplied standoffs installed.
The replace is supplied with two standoffs. Bend and install these
standoffs on top of the replace ensuring that the height of the standoff
maintains a 6" clearance.

Installing the standoff's.
 Installing the Nailing Flange Extension.

Once the replace is placed into the rough framed opening, the supplied
Nailing Flange Extension (Part No. L42087) must be fasten securely into
place, with nails or wood screws. as shown in Figure 8.
 The nailing ange extension can be substituted with a piece of
 material of the same size and thermal characteristics,
ie: cement board or equivalent. This is recommended in applications
where the facing materials will not adhere to the metal nailing ange.
6"
Clearance from top of replace to a combustible ceiling within
the replace enclosure.
When installing a shelf over the top of the replaces, the following
guidelines must be adhered to:
For  applications, the minimum clearance is 2" from the rear of
the replace to a wall, or any combustible materials, and 10" clearance
from the top of the replace to the underside of any combustible shelf
materials.
For  applications, the minimum clearance is 2" from the rear
of the replace to a wall, or any combustible materials, and 21" to the
underside of any combustible shelf materials.