Owner`s manual


L42DF* Indoor Gas Fireplace
XG0181 - 112811.1
Maintenance


The following is a troubleshooting chart of possible problems:
 
Noisy Pilot Flame Locate pilot adjustment screw on gas
control valve. Flame is decreased by
turning adjustment screw clockwise.
Pilot won’t ignite Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram .
Main burner will not ignite
1. Check wiring (see ).
2. Check wall switch for proper
connection.

The following is a troubleshooting chart of possible problems:
 
Pilot won't ignite or spark. - Check the on the batteries on the
remote or the receiver.
- Check the green LED on AC adaptor
-Check the green ground wire under
the valve
Main burner will not light. - Check the wiring on the valve as per
diagram
Fan not working - Make sure the fan speed control is on.
- 10 minute delay to turn on.
If your replace still does not operate correctly, consult your local Montigo dealer.

All spare parts, optional fans, and optional trim nishes are available from your local Montigo dealer.