Owner`s manual


L42DF* Indoor Gas Fireplace
XG0181 - 112811.1
Maintenance
See pages 25 to 26.
General
Have the replace and installation inspected yearly.
The inspection must include, but is not limited to, the
following:
A visual check of the entire vent system and termination.
An inspection of the explosion relief appers and the door gaskets
to ensure a proper seal.
An inspection of the burner, vent run, and primary air openings.
An inspection of the gas valve, gas components, and pilot ame.
For your convenience a 1/8" manifold pressure tap is supplied
on the gas valve for a test gauge connection.
Inspection of all optional equipment; fans, thermostats, etc.
For Natural Gas this appliance requires a minimum inlet pressure
of 5.5" W.C. and a manifold pressure of 3.5" W.C.
For Propane Gas this appliance requires a minimum inlet pressure
of 11" W.C. and a manifold pressure of 10" W.C.
Always keep the replace area clear and free of combustible
materials, as well as gasoline and other ammable vapors and
liquids.
Do not use this appliance if any part has been under water.
Immediately call a qualied service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.

When the replace is rst activated, there may be some smoke and a
visible lm may be left on the glass. This is a normal condition, and is
the result of burning of protective coatings on new metal.
Glass must be cleaned periodically to remove any lm (which is
a normal by-product of combustion) which may be visible. Film
can easily be removed by removing the door, as shown on 
. Handle the door carefully, and clean it with non-abrasive glass
cleaners. One of the most effective products is Kel Kem.
Silicone seals on inner door during initial ring will "off gas",
leaving a visual deposit of a white substance on combustion
chamber walls. This can easily be removed from the chamber
walls using normal household products.
Use a vacuum cleaner or whisk broom to keep the control
compartment, burner, and rebox free from dust and lint.

The is equipped with an adjustable burner, allowing you to raise
or lower the ames. To adjust the ames, locate the black knob marked
'Hi-Lo', in the centre of the gas control valve (See Figure 29).
To raise the ame height, turn the black knob (located behind the
lower control compartment) .
To lower the ame height, turn .
 'Hi-Lo' Adjustment on the SIT Nova 820 gas valve,

The is equipped with an adjustable burner, allowing you to raise
or lower the ames. To adjust the ames, locate the black knob marked
'Hi-Lo', in the centre of the gas control valve (See Figure 30).
To raise the ame height, turn the black knob (located behind the
lower control compartment) .
To lower the ame height, turn .
 'Hi-Lo' Adjustment on the SIT Proame gas valve.
Manifold Pressure
Test Connection
Pilot Adjustment Screw
Hi Lo Adjustment
Inlet Pressure
Test Connection

 Locate Pilot Adjustment Screw. (See gure 29 or 30.)
 Adjust pilot screw to provide properly sized ame as shown.
 After installing or servicing, leak test with a soap solution with main
burner on. Coat pipe and tubing joints, gasket etc. with soap solution.
Bubbles indicate leaks. Tighten any areas where the bubbles appear
until the bubbling stops completely.
Manifold Pressure
Test Connection
Wall Switch
Power
Generator
Pilot Adjustment Screw
Inl
e
t Pr
essu
r
e
'Hi-Lo' Adjustment Knob
Gas Control Knob
(Shown in “Pilot” position)