Owner`s manual
XG0147 - 011912.1
Installation
Flue cover and collar removal, Top Vented replace.
Flue cover and collar installation, Rear Vented replace.
Use the following instructions to convert an for Rear Vent use:
1. Remove the Rear ue cover and gasket (5" and 8") on the ue
outlet, as shown in Figure 8.
2. Next, Remove the Top ue collar's (5" and 8") on the ue outlet,
as shown in Figure 8.
3. Install the (removed) Rear ue cover and gasket material, to the
Top vent outlet. Fasten the cover with included hardware, as
illustrated Figure 8a.
4. Install the (5" and 8") collars to the rear vent outlet using the
included hardware, as illustrated Figure 8a.
5” Inner Flue Collar
8” Outer Flue Collar
Flue Gasket
Flue Cover Plate
8” Outer Flue Collar
5” Inner Flue Collar
Flue Gasket
Flue Cover Plate
Montigo supplies a variety of direct venting and termination options.
It should also be
selected such that it provides the shortest vent run possible. Should it
be impossible to ensure that the termination is the highest point or to
meet the venting guidelines laid out below please contact your Montigo
dealer to discuss power venting options.
Venting originates from the unit through the top or through the rear
Venting can terminate through the roof or through an exterior wall.
Refer to - Termination Locations to ensure the
planned termination location is acceptable.
Once the termination location has been established, refer to the
appropriate section below for installation details
All replaces shipped from the factory are Top vent.
Air Bafe is shipped open. If you are top venting, the air bafe
should be closed following these steps:
Air Bafe in Open position
Pull the air bafe forward as far as possible and screw the air bafe
closed.
Air bafe in closed position