Installing The Fireplace Shell
The HWDF-Seriesreplacemaybeinstalledinanylocationthatmain-
tains proper clearances to air conditioning ducts, electrical wiring and
plumbing.Safety,aswellasefciencyofoperation,mustbeconsidered
whenselectingthereplacelocation.Trytoselectalocationthatdoes
notinterferewithroomtrafc,hasadequateventilation,andoffersan
accessible pathway for Direct Vent installation. Refer to page 4 - Vent
Installation for more information.
Thereplacedimensionsareshownbelow:
When installing a shelf over the top of the replace, the following
guidelines must be adhered to: For Rear Vent applications the
minimumclearancefromthetopofthereplacetoashelfis9".For
Top Vent applications, theminimumclearance is 17 1/2".(Minimum
2" clearance must still be maintained around the vent pipes.)
Figure 4. Framing for shelves over the replace.
Top Vent
Figure 3. Minimum Corner framing dimensions, using a 45° elbow.
Figure 2. Framing dimensions.
* When sheetrock is
not used behind the
fireplace, framing
depth may be reduced
by 5/8"
Framing
WARNING:
When this appliance is installed directly on carpeting, tile or
anycombustiblematerialotherthanwoodooring,itmustbe
installed on a metal or wood panel extending the full width and
depth of the appliance.
Rear Vent
* Clearance from top of the Fireplace to a combustible ceiling within the fireplace
enclosure.
** Refer to Pages, 10 & 11.
22
1/8
3
7 3/4”
42 1/2”
Top View
Front View
Side View
Clearances
These clearances apply to all dimensions except the framed opening,
where the clearance to combustibles is 0". The HWDF-Series clearance
tounprotectedcombustiblewallswhichareperpendiculartothereplace
opening, must not project beyond the shaded area shown in Fig. 24.
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapor barrier. This will reduce
thepossibilityofacold-airconvectioncurrentonthereplace.
The HWDF Series clearances to combustible materials are:
Figure 1. Fireplace dimensions.
G
H
J
K
C
L
I
C
L
K
J
G
B
K
J
L
Not Available
Top - Rear Vent *
10"
Top - Top Vent
17 1/2”
Back
3"
Sides
1"
Floor
0"
Mantle**
4"
HW38DFHW34DF
9"
17 1/2”
3"
1"
0"
4"
9"
1"
1"
0"
4"
17 1/2”
HW42DF
Not
Available
Not Available
Not
Available
N.G. 4/7
L.P. 5/8
N.G. 5/8
L.P. 4/7
N.G. 4/7
L.P. 5/8
N.G. 5/8
L.P. 4/7
42 1/2
45
9”
37
Header
Header
Shel
f
MELS hort
Shelf
2
8 3/4
42 1/2
17 1/2”
18” Max
62 1/2
0" c
l
earance
to corners only
37
3/4
47 1/2”
B
A
C
D
D
D
F
6 1/4”
5 1/4”