Owner`s manual
Page 4
HT34-PV Series Power Vent Gas Fireplace
Part No. XG0530 - 041510
Installation
Installing The Fireplace Shell
The replace may be installed in any location that maintains proper clear-
ances to air conditioning ducts, electrical wiring and plumbing. Safety,
as well as efciency of operation, must be considered when selecting
the replace location. Try to select a location that does not interfere
with room trafc, has adequate ventilation, and offers an accessible
pathway for Power Vent installation. Refer to page 4 - Vent Installation
for more information.
The replace dimensions for HT34-PV models are shown below:
When installing a shelf over the top of the replace, the following
guidelines must be adhered to: For Rear Vent applications the
minimum clearance from the top of the replace to a shelf is 9". For
Top Vent applications, the minimum clearance is 17 1/2". (Minimum
2" clearance must still be maintained around the vent pipes.)
Figure 4. Framing for shelves over the replace.
Top Vent
Figure 3. Minimum Corner framing dimensions, using a 45° elbow.
Figure 2. Framing dimensions.
* When sheetrock is
not used behind the
fireplace, framing
depth may be reduced
by 5/8"
Framing
Top View
Front View
Side View
Clearances
These clearances apply to all dimensions except the framed opening,
where the clearance to combustibles is 0". The HT34-PV Series
clearances to combustible materials are:
Unprotected combustible walls which are perpendicular to the replace
opening, must not project beyond the shaded area shown in Figure 25.
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapor barrier. This will reduce
the possibility of a cold-air convection current on the replace.
Figure 1. Fireplace dimensions.
Rear Vent
* Clearances from the top of the replace to a combustible ceiling
within the replace enclosure.
** Refer to page 14.
WARNING!
When this appliance is installed directly on carpeting, tile or any
combustible material other than wood ooring, it must be installed
on a metal or wood panel extending the full width and depth of
the appliance.
52 5/8”
34”
37 3/8”
0” clearance to
corners only
20”
53 3/4”
34”
Note: PV venting Not exactly as shown.
17 3/8”
4
8”
7”
4”
40 1/4”
47 3/8”
47 7/8”
1 1/4”
1”
31 3
/
8”
Opening
1 1/4”
1 1/4”
5 1/2”
5 1/4”
37 1/8”
Opening
17 3/8”
22”
9 1/2”
C
L
7”
4”
33 7/8”
M
T
9”
S
Header
Header
Shelf
MEL Short
Shel
f
L
M
17 1/2”
Power Vent
HT34-PV
Top - Rear Vent *
9"
Top - Top Vent
17 1/2”
Back
2"
Sides
1"
Floor
0"
Mantle**