fire feature www.montigo.com Installation Operation & Maintenance Manual Check local codes and read all instructions prior to installation. HT34-PV Indoor HT-Series PV Gas Fireplace Warning: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
HT34-PV Series Power Vent Gas Fireplace Warning: Read this manual before installing, operating or troubleshooting this appliance. Please retain this owner's manual for future reference. Congratulations Congratulations on selecting a Montigo gas fireplace, an elagent and well designed gas fireplace built to your specifications. The Montigo gas fireplace you have selected is designed to provide the utmost in safety, reliability, and engineering standards.
HT34-PV Series Power Vent Gas Fireplace Introduction Thank You for choosing a Montigo Gas Fireplace. About this Fireplace: The HT34-PV Series is an fireplace that is designed to compliment your home and decor. This fireplace can be converted to both a Top Vent or Rear Vent application, but requires a Power Vent for safe and trouble free operation. (Refer to the Index) The HT34DF-PV Series is available in the specific models below. The HT34-PV is rated for Natural Gas and Liquid Propane at 30,000 Max.
HT34-PV Series Power Vent Gas Fireplace Installation Installing The Fireplace Shell Framing The fireplace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing. Safety, as well as efficiency of operation, must be considered when selecting the fireplace location. Try to select a location that does not interfere with room traffic, has adequate ventilation, and offers an accessible pathway for Power Vent installation.
HT34-PV Series Power Vent Gas Fireplace Installation Installing The Gas Line Vent Installation The gas line must be installed before finishing the HT34-PV Series Fireplace. Natural Gas requires a minimum inlet gas supply pressure of 5.5" W.C. & a manifold pressure of 3.5" W.C. Propane Gas requires a minimum inlet gas supply pressure of 11" W.C. & a manifold pressure of 10" W.C. Provision must also be made for a 1/8" N.P.T.
HT34-PV Series Power Vent Gas Fireplace Installation Installing Terminations with Built-In Frames Installing Heat Guards over Terminations 11 MTO-3F (4"/7") 11 Figure 6a. Installing a MTO termination. MTKOG (4"/7") PTKOG (5"/8") Figure 6d. Installing a MTO termination heat guard. 1. Frame the termination opening to 11" x 11". 1. 2. Fasten the termination to the studs using a minimum of 4 screws. Ensure that the two long mounting brackets are facing the bottom of the termination. (See inset).
HT34-PV Series Power Vent Gas Fireplace Installation Converting to Top Vent/ Rear Vent HT34-PV Top Vent Use the following instructions to convert an HT34-PV for Top Vent use: 1. Install the 4" inner flue cap on the rear flue outlet and secure the cap in place with five screws, as shown in figure 7a. 2. Install the flue gasket material and flue cover plate on the rear vent outlet . Fasten the plate with four screws, as illustrated below. 3.
HT34-PV Series Power Vent Gas Fireplace Installation Installing The Horizontal & Vertical Exterior Power Vent A Power Vent is required for the HT34-PV rear or Top vent gas fireplace. There are four 4/7 Power Vent models available. These Power Vents are required for Superior venting, safe operation & years of trouble free operation. The available Montigo Power Vent models are: LDVPV47 (Linear, Interior In-line Power Vent, document, XG0700). EDVPV47 (External Power Vent Module, document, XG0750).
HT34-PV Series Power Vent Gas Fireplace Installation Wiring Gas Control and Pilot Wiring HT34-PV-I Honeywell (Q3450) Pilot Assembly Pilot Electrical Harness Connector Honeywell Gas Control (SV9501M) Gas Control Connector Fan Plug Receptacle Junction Box Black White Green 115VAC 24VAC Gnd Screw 40 VA Transformer Wall Switch Figure 26. Wiring for the HT34-PV-I with Honeywell gas control and pilot.
HT34-PV Series Power Vent Gas Fireplace Installation Removing and Installing the Door Removing the door: The HT34-PV Series door is removed in a few simple steps. Follow these Steps below to remove the Horizontal access panel, unlatch the door buckles and, remove the door. Replace in reverse order. Step 1: Remove the Horizontal Access Panel: Remove the Horizontal cover by placing fingers in both finger holes, then pushng away from you and lifting out.
HT34-PV Series Power Vent Gas Fireplace Installation WARNING! Do not attempt to clean glass when hot. L42DF-ST Do not clean glass with abrasive materials as any glass etching may cause premature glass failure. Do not operate this fireplace without the glass door, or with a broken glass door. Installing the HT34-PV Log Set Installing the Logset: The HT34-PV can be supplied from the factory with one Large ceramic fibre log. Unpack the log and handle it very carefully. Place behind the burner as shown.
HT34-PV Series Power Vent Gas Fireplace Operation - Model HT34-PV-I HT34-PV-I with Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition system that lights the pilot burner automatically. Do not attempt to light the pilot by hand. B. BEFORE LIGHTING smell all around the appliance area for gas.
HT34-PV Series Power Vent Gas Fireplace HT34-PV-F Operation - Model HT34-PV-F with Proflame SIT Electronic Ignition with American Ignition For Your Safety -Flame READ Electronic BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition system that lights the pilot burner automatically. Do not attempt to light the pilot by hand. B.
HT34-PV Series Power Vent Gas Fireplace Operation Maintenance Lighting Instructions General ■ Have the fireplace and installation inspected yearly. The inspection must include, but is not limited to, the following: See pages 12 to 14. • A visual check of the entire vent system and termination. • An inspection of the explosion relief flappers and the door gasketing to ensure a proper seal. • An inspection of the burner, venturi, and primary air openings.
HT34-PV Series Power Vent Gas Fireplace Maintenance Troubleshooting HT34-PV-I HONEYWELL SV9500 /9600 Troublshooting Sequence Troubleshooting Follow this information to reset the SIT System: HT34-PV-F 1. Locate the lead to the battery backup, (remove) (Refer to schematic, below) NOTE: Before Troubleshooting, Familiarize Yourself With START The Startup And Checkout Procedure.
HT34-PV Series Power Vent Gas Fireplace Warranty The Warranty The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve and fibre logs. Glass, plated/painted finishes, and refractory lining are exempt.
HT34-PV Series Power Vent Gas Fireplace Appendix A - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, or balcony [16 inches (41 cm) minimum] N= B = clearance to door, or sides and top of window, that may be opened [16 inches (41 cm) minimum for appliances ≤100 000 BTU/H (30kW)] P = clearance under veranda, porch, deck, or balcony [16 inches (41 cm) minimum‡ to non-combustibles] [22 inches (56 cm) minimum‡ to combustibles] clearance above paved sidewalk or
HT34-PV Series Power Vent Gas Fireplace Appendix B - State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.
HT34-PV Series Power Vent Gas Fireplace Notes Part No.
XG0530 - 041510 Canadian Heating Products Inc. Montigo Del Ray Corp.