H(L)38DF-PRC Indoor Panorama Gas Fireplace
Part No. XG0211 - 080510
3.0”
Section 2: Framing
Installation
1). Frame in the enclosure for the unit with framing materials. The
framed opening for the assembled replace is 40 7/8" wide, x 44"
high x 24 5/8" deep, see Figure 2
.
NOTE: When constructing the framed opening, please ensure
there is access to install the gas line when the unit is installed.
See Figure 22.
Figure 2. Framing dimensions.
Clearances
When installing a shelf over the top of the replaces, the following
guidelines must be adhered to:
For Rear Vent applications, the minimum clearance is 2" from the rear of
the replace to a wall, or any combustible materials, and 11" clearance
from the top of the replace to the underside of any combutible shelf
materials.
For Top Vent applications, the minimum clearance is 2" from the rear of
the replace to a wall, or any combustible materials, and 17 1/2" to the
underside of any combutible shelf materials.
(Minimum 2" clearance must still be maintained around the vent
pipes.)
Figure 4. Framing for shelves over the replace.
Top VentRear Vent
Installing The Standoffs
To avoid elevated mantel temperatures, all H*38PR* gas
replaces are required to have the supplied standoffs installed.
The replace is supplied with two standoffs. Bend and install these
standoffs on top of the replace ensuring that the height of the standoff
maintains a 3" clearance.
Figure 6. Installing the H*38PR* standoffs.
46”
17 1/2”
MEL Short
90 elbow
shelf
Framing / Header
44”
2 Min.”
11”
29
Framing Header
shelf
33”
44”
12”
Max
2 Min.”
24 1/2”
40 3/4”
44”
Clearance to Combustibles
Top- top vent 11"
Top- rear vent 17 1/2"
Header (from oor) 44"
Sides 0"
Front** 0"
Back 1"
Venting - top 2"
Venting- sides, bottom 1"