Owner`s manual

Page 24
H(L)38DF-PRC Indoor Panorama Gas Fireplace
Part No. XG0211 - 080510
Maintenance
General
Have the replace and installation inspected yearly. The inspection
must include, but is not limited to, the following:
A visual check of the entire vent system and termination.
An inspection of the explosion relief appers and the door
gasketing to ensure a proper seal.
An inspection of the burner, venturi, and primary air openings.
An inspection of the gas valve, gas components, and pilot ame.
For your convenience a 1/8" manifold pressure tap is supplied
on the gas valve for a test gauge connection.
Ensure proper log placement as per this manual.
Inspection of all optional equipment; fans, thermostats, etc.
For Natural Gas this appliance requires a minimum inlet pressure
of 5.5" W.C. and a manifold pressure of 3.5" W.C.
For Propane Gas this appliance requires a minimum inlet pressure
of 11" W.C. and a manifold pressure of 10" W.C.
Always keep the replace area clear and free of combustible materials,
as well as gasoline and other ammable vapors and liquids.
Do not use this appliance if any part has been under water. Immediately
call a qualied service technician to inspect the appliance and to
replace any part of the control system and any gas control which
has been under water.
Cleaning
When the replace is rst activated, there may be some smoking and
a visible lm may be left on the glass. This is a normal condition, and is
the result of burning of protective coatings on new metal.
Glass must be cleaned periodically to remove any lm (which is
a normal by-product of combustion) which may be visible. Film
can easily be removed by removing the door, as shown on Page
17. Handle the door carefully, and clean it with non-abrasive glass
cleaners. One of the most effective products is Kel Kem.
Silicone seals on inner door during initial ring will "off gas", leaving
a visual deposit of a white substance on combustion chamber walls.
This can easily be removed using normal household products.
Use a vacuum cleaner or whisk broom to keep the control
compartment, burner, and rebox free from dust and lint.
Logs may be cleaned periodically with a vacuum to remove soot or
other contaminates.
Lighting Instructions
See pages 21 to 23
Burner Adjustment
The H*38PR* is equipped with an adjustable burner, allowing you to
raise or lower the ames. To adjust the ames, locate the black knob
marked 'Hi-Lo', in the centre of the gas control valve (See Figure 32).
The front burners are not adjustable.
p To raise the ame height, turn the black knob (located behind
the lower trim) counter-clockwise.
p To lower the ame height, turn clockwise.
Figure 32.
'Hi-Lo' Adjustment on the H*38PR* s gas valve.
Note: H*38PR- I2 models (SIT-IPI electronic ignition) do not
feature hi/lo adjustment.
'Hi-Lo' Adjustment Knob
CAUTION!
Fireplace gas control must be in the “OFF” position and pilot
and main burners extinguished when cleaning appliance with
a vacuum.
Doors can get very hot. Handle only when cool.