H(L)38DF-PRC Indoor Panorama Gas Fireplace
Part No. XG0211 - 080510
A
C
B
18”
59”
Figure 16. Rear Vent Venting Graph for wall mounted terminations.
If your installation does not fall
within the venting graph para-
meters, please contact Montigo
for Power Venting options.
Figure 16b. Rear Vented, wall mounted Multi-elbow termination
installation. Installation for H*38PR* must have a minimum
vertical rise of 59".The vent run must comply with the Venting
Graph for Rear vent, wall mounted terminations, Figure
16.
NOTE: This conguration is available to ALL installations
of Rear vent, Wall Terminations except straight through
the wall installations, as shown in gure 16a.
Figure 16a. Straight run, Rear Vented, wall mounted termination for
H*38PR*.
NOTE: This venting conguration DOES NOT comply
with the Venting Graph for Rear vent, wall mounted
terminations, Figure 16. This straight through the wall
vent run can ONLY be congured as shown.
33”
PXT Extension
RHS101 Heat
Shield
Termination
Hearth
Exterior
Wall
NOTE:
12” MAX. horizontal
run with no vertical lift.
12” MAX.
46” Max.
59” Min.
18”
Max.
Flex or Rigid
Section
26”
Min.
33”
Installation
Notes Wall Mounted Terminations: Rear Vent
All dimension lengths for vertical or horizontal runs are measured
from center of the vent pipe.
Venting runs must fall within the limits set by the venting graphs,
see Figure 16.
Fireplace must be converted to Rear Vent conguration prior to
running vent, see Figure 7 and 8.
The Venting Graph
Measure the vertical height from the replace hearth to the centre of the
termination and the horizontal run from the replace ue collar to the wall
ange of the termination. Plot on the Venting Graph Figure 16 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 84" and the horizontal
run to the wall ange of the vent termination is 48", this would be
an acceptable installation.
Example B: (Uncceptable Installation)
If the vertical dimension from the hearth is 90" and the horizontal
run to the wall ange of the vent termination is 126", this would be
would NOT be an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the oor of the replace is 66" and
the horizontal run to the wall ange of the vent termination is 90",
this would NOT be an acceptable installation.