The following is a troubleshooting chart of possible problems:
Troubleshooting
SIT Nova 820
The following is a troubleshooting chart of possible problems:
PROBLEM CORRECTIVE ACTION
Noisy Pilot Flame Locate pilot adjustment screw on
gas control valve. Flame is decreased by
turning adjustment screw clockwise.
Pilot won’t ignite Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram gure 29.
Main burner will 1. Check wiring (see gure 29).
not light 2. Check wall switch for proper
connection.
PROBLEM SOLUTION
Pilot won't ignite or spark. - Check the on the batteries on the
remote or the receiver.
- Check the green LED on AC adaptor
-Check the green ground wire under
the valve
Main burner will not light. - Check the wiring on the valve as per
diagram Fig 18
Honeywell Electronic Ignition
The following is a troubleshooting chart of possible problems:
If your replace still does not operate correctly, consult your local Montigo dealer.
All service and repairs should be performed by a qualied Technician.