Owner`s manual
H*38DF PRC Panorama Indoor Gas Fireplace
Page 18
XG0211 - 040912.1
Installation
Section 4: Wiring
Figure 18. Wiring Diagram for the SIT Proame Electronic Ignition
Figure 20. Wiring with Honeywell gas control and pilot.
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Junction Box
115VAC
24VAC
40 VA
Transformer
Black
White
Green
Gnd Screw
Wall Switch
Fan Plug
Receptacle
Manifold Pressure
Test Connection
Wall Switch
Power
Generator
Pilot Adjustment Screw
Inl
e
t Pr
essu
r
e
'Hi-Lo' Adjustment Knob
Gas Control Knob
(Shown in “Pilot” position)
Figure 19. Wiring Diagram for SIT Nova 820 gas and pilot.
REMOTE
Receiver 14
Pin Connector
Pilot
(CPI / IPI MODE
MOTOR
IPI/CPI
RECEIVER
SPLIT FLOW
ON / OFF
TH
TPTH
DC SUPPLY
GROUND
885 Valve
Orange
Green
Chassis
connection
Remote control
Not Used)
Battery
Holder
4 x 1.5V
AA Type
120 Vac INPUT
7.5V DC
Output
AC
Adaptor
Receiver 14
Battery Holder
w/ Switch
ON/REMONTE/OFF
(Not Used)
Receiver 14
Battery Holder
Top View
Models
H38DFPRCN-I
H38DFPRCL-I
Models
H38DFPRCN H38DFPRCL
Models
H38DFPRCN-F HL38DFPRCN-F HPDFPRCN-F
H38DFPRCL-F HL38DFPRCL-F HP38DFPRCL-F
Installing the remote On/Off Wall Switch
The H*38PR* gas valve may be connected to a wall switch. Do NOT
connect any external power to the remote switch. The valve will
generate its own power on a millivolt circuit or will draw its power from
an AC Connection inside the replace, depending on the model of the
unit. Use only low voltage wire, and DO NOT connect any external
power to the remote switch.
NOTE: The switch location must not exceed 30' from the replace.
NOTE: If any of the original wire supplied with the appliance is replaced,