Installation & Maintenance Manual H38DF PRC HL38DF PRC HP38DF PRC Panorama Indoor Residential Gas Fireplace WARNING DANGER Read and understand this manual. Improper installation, adjustment, alteration, service or maintenance can cause serious injury, property damage or even death. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
H*38DF PRC Panorama Indoor Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance. Table of Contents INTRODUCTION ..................................................................................3 BEFORE YOU START:........................................................................4 Section 4: Wiring . ......................................................
H*38DF PRC Panorama Indoor Gas Fireplace Safety Alert Key DANGER Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury or property damage. WARNING Indicates a hazardous situation which, if not avoided, COULD result in death or serious injury or property damage. CAUTION Indicates a hazardous situation which, if not avoided, WILL result in minor or moderate injury.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Installationand repairs should be done by an authorizedgas fireplace service technician. The applianceshouldbe inspectedbeforeuse and at least annuallyby a professional.More frequesntcleaning may be required due to exessive lint from carpeting,bedding material, etc. It is imperativethat control compartments,burners and circulatingair passagewaysof the fireplace are kept clean .
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions Please review the Pre-Installation Checklist on Page 4 for general information on preparing for a successful installation of your fireplace. The H*38PR* fireplace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing. Safety, as well as efficiency of operation, should be considered when selecting the fireplace location.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 2: Framing 1). Frame in the enclosure for the unit with framing materials. The Top Vent framed opening for the assembled fireplace is 40 3/4" wide, x 44" high x 24 1/2" deep, see Figure 2. NOTE: When constructing the framed opening, please ensure there is access to install the gas line when the unit is installed. See Figure 21. Min. 1 ” Ceiling level Non-Combustible materials. Alcove over fireplace.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Nailing Flange Extension When installing a shelf over the top of the fireplaces, the following guidelines must be adhered to: For Rear Vent applications, the minimum clearance is 1" from the rear of the fireplace to a wall, or any combustible materials, and 11" clearance from the top of the fireplace to the underside of any combustible shelf materials.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 3: Venting Montigo supplies a variety of direct venting and termination options. The direct vent termination location MUST be selected such that it is the highest point in the venting assembly. It should also be selected such that it provides the shortest vent run possible.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 3-2: INSTALLING A ROOF MOUNTED DIRECT VENT TERMINATION (PVTK-1) This section applies to installations where the direct vent termination will be roof mounted. Section 3-2-1: VENTING LAYOUT Selection of components and details of venting lay out should adhere to the following guidelines: The maximum termination point is 32’ above the fireplace (NOTE: if the maximum termination height is used, the flame pattern may be affected).
H*38DF PRC Panorama Indoor Gas Fireplace Installation PVTK1 Termination Storm Collar Support plate 32’ M a.x Support ring 12” Max. Figure 9c. Rear vent, Roof mounted venting (1 = 90° bend). Page 10 XG0211 - 040912.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 3-3: INSTALLING A WALL MOUNTED DIRECT VENT TERMINATION This section applies to installations where the direct vent termination will be wall mounted. 4). Installation of termination from inside structure A Termination with a MOSR Frame is installed from the inside of the structure. These are commonly used in high-rise construction. 1).
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 3-3-1: VENTING LAYOUT Selection of components and details of venting layout should adhere to the following guidelines: Vent terminations must not be recessed in walls or siding. For Heat Shield requirements see Section 3-3-3 on page 17. Once the proposed venting layout has been determined refer to either Figure 12, 12a, 14, or 14a to ensure the layout is acceptable.
H*38DF PRC Panorama Indoor Gas Fireplace Installation 150”max. Heat Shield Termination Solid Section Flex Section Hearth Exterior Wall Figure 13b. H38PR*, HL38PR*, or HP3PR* Top Vented, wall mounted Multielbow installation. See Venting Graph for Top vent, wall mounted terminations, Figure 12 or 12a. 126” Max. 30” Max. Heat Shield Termination Flex Section Solid Section Exterior Wall Hearth Figure 13c. H38PR* , HL38PR* or HP38PR* Top Vented, wall mounted Retracted Multi-elbow installation.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Notes Wall Mounted Terminations: REAR VENT All dimension lengths for vertical or horizontal runs are measured from center of the vent pipe. Venting runs must fall within the limits set by the venting graphs, see Figure 14 or 14a. Fireplace must be converted to Rear Vent configuration prior to running vent, see Figure 8 and 8a. Acceptable vent run within non-shaded area.
H*38DF PRC Panorama Indoor Gas Fireplace Installation 46” Max. Flex or Rigid Section 26” Min. 59” Min. 12” Max. 33” Figure 15a. H38PR* or HL38PR* Rear Vented, wall mounted Multi-elbow termination installation. The vent run must comply with the Venting Graph for Rear vent, wall mounted terminations, Figure 14. 42” Max. Flex or Rigid Section 26” Min. 59” Min. 12” Max. 33” Figure 15b. HP38PR* Rear Vented, wall mounted Multi-elbow termination installation.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 3-3-2: VENTING COMPONENTS The following components and associated Montigo part numbers for installation of a roof or wall mounted termination. Use only Montigo Vent Components. Use of non-Montigo parts will VOID the warranty and may impede operation of the fireplace..
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a Wall Mounted RHS8 Heat shield The RHS8 Heat shield CANNOT be used when the Termination is WITHIN 36" Min. horizontal and 60" Min. vertical from the fireplace, or directly off the rear of the fireplace, as shown figure 16a. The RHS101 Heat Shield (Figure 17 and 17a) MUST be used within the noted dimensions. To install the RHS8, frame an opening in combustible construction, Figure 16 below.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 4: Wiring Receiver 14 Battery Holder w/ Switch ON/REMONTE/OFF REMOTE Receiver 14 Pin Connector MOTOR Models H38DFPRCN-F HL38DFPRCN-F HPDFPRCN-F H38DFPRCL-F HL38DFPRCL-F HP38DFPRCL-F Orange Pilot Green Receiver 14 Battery Holder Top View (Not Used) RECEIVER 885 Valve SPLIT FLOW Chassis connection ON / OFF GROUND TPTH TH Remote control DC SUPPLY IPI/CPI AC Adaptor 120 Vac INPUT Battery Holder 4 x 1.5V AA Type 7.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 5: Installing the Gas Line Section 5-1: FUEL CONVERSION Verify that your fireplace is compatible with your available gas type. (Natural Gas or Propane shown by "N" or "L" in your model number If gas type is not compatible, contact your local Montigo representative to purchase a conversion kit. Conversion kits must be installed by a qualified service technician.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 6: Finishing Mantels & Surrounds Finishing Around the Fireplace Combustible mantels and mouldings may be safely installed over the top and on the front of the fireplace provided that they do not project beyond shaded area shown in Figure 22.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 7: Installing & Removing the Door Removing the door: The H*38PR* doors are removed in a few simple steps. Follow these instructions below to remove the Horizontal access panel, unlatch the door buckles and, remove the door. Replace in reverse order. Remove the Horizontal Access Panel: Step 1: Remove the Horizontal cover by placing fingers in both finger holes, then pushing away from you and lifting out.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 8: Installing the Accessories Installing the H38PR* Logset The H38PR* is supplied with eight (8) fibre logs. The two small bottom logs ("A" ) are mounted on the burner grate by placing them diagonally onto the supplied Log stands. The long Front / Back logs ("B") are placed against the grate as shown in Figure 25b. Note: When placing logs, arrange Logs "B" as not to cover Burner holes.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Installing the HP38PR* Logs and Embers Bottom Logs The HP38PR* is supplied with seven (7) fibre logs. The two bottom logs ("A" & "B") are mounted on the burner grate as shown in Figure 26a. Log E Top Logs Place logs "C" & "D" into their diagonal positions as shown in Figure 26b. Log "E" is mounted on top of log 'C" as shown in Figure 26c. Place log "F" and log "G" into slots at each side of the unit as seen in Figure 26d.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Installing Firestones in Natural Gas and Propane Fireplaces The HL38PR* fireplace is supplied with firestones. Remove the Door as shown on page 21. Follow these instructions to ensure all parts are removed or replaced as required. Once the glass door is removed place the firestones randomly across the pan as described in Figure 27 to 27a. .
H*38DF PRC Panorama Indoor Gas Fireplace Operation Section 9: Start up Sequence Standing (Continuous) Pilot Ignition (SIT NOVA 820) For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. A. This appliance has a pilot which must be lit by hand. When lighting the pilot, follow these instructions exactly. B.
H*38DF PRC Panorama Indoor Gas Fireplace Operation SIT Proflame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. A. This appliance is equipped with an ignition system that lights the pilot burner automatically. Do not attempt to light the pilot by hand. B.
H*38DF PRC Panorama Indoor Gas Fireplace Operation Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. A. This appliance is equipped with an ignition system that lights the pilot burner automatically. Do not attempt to light the pilot by hand. B.
H*38DF PRC Panorama Indoor Gas Fireplace Maintenance Hi-Lo Burner Adjustment: (SIT Nova 820). Lighting Instructions See pages 25 to 27. General Have the fireplace and installation inspected yearly. The inspection must include, but is not limited to, the following: • A visual check of the entire vent system and termination. • An inspection of the explosion relief flappers and the door gaskets to ensure a proper seal. • An inspection of the burner, vent run, and primary air openings.
H*38DF PRC Panorama Indoor Gas Fireplace Maintenance Troubleshooting SIT Nova 820 The following is a troubleshooting chart of possible problems: PROBLEM CORRECTIVE ACTION Noisy Pilot Flame Locate pilot adjustment screw on gas control valve. Flame is decreased by turning adjustment screw clockwise. Pilot won’t ignite Disconnect remote wires and try to light pilot. If pilot now works, remote connections are faulty. Check wiring diagram figure 29. Main burner will not light 1.
H*38DF PRC Panorama Indoor Gas Fireplace Replacement Parts Installation MODEL# H38PR* HL38PR* HP38PR* NG Gas Valve RGC1006 RGC1006 TBA LG Gas Valve RGC1005 RGC1005 TBA NG Pilot RPA020 RPA020 TBA LP Pilot RPA021 RPA021 TBA Burner Assembly NG Contact your local Montigo Dealer Burner Assembly LPG Logs RLG547 RLG547 TBA All service and repairs should be performed by a qualified Technician.
H*38DF PRC Panorama Indoor Gas Fireplace Appendix Appendix A: Venting Terminations Location Canada* USA** A clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches B clearance to top of doors or operable windows 12 inches 12 inches C clearance to sides or bottom of door or operable windows 9 inches 12 inches D clearance to permanently closed window when installed with approved gas penetration termination 0 0 E clearance to permanently closed
H*38DF PRC Panorama Indoor Gas Fireplace Appendix B: Warranty Appendix The Warranty The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo fireplace, there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve, fibre logs and Power Vent Module.
H*38DF PRC Panorama Indoor Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.
H38DF PRC Panorama Gas Fireplace Ferndale, Washington TF: 1.800.789.6236 FX: 1.866.3000.0927 XG0211 - 040912.1 Langley, British Columbia TF: 1.800.378.3115 FX: 1.604.607.