Installation Operation & Maintenance SP28-F2 5" B-Vented Gas Fireplaces Warning: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. For Your Safety: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
SP28-F2 Modular Series Fireplace Introduction Table Of Contents Introduction ............................................................................ 2 Installation ......................................................................... 3-11 Installing the Fireplace Shell ........................................... 3 Installing the Gasline ....................................................... 4 The Remote Switch ........................................................ 4 Vent Requirements .........
SP28-F2 Modular Series Fireplace Installation Installing The Fireplace Shell The fireplace may be installed in any location that is free of air conditioning ducts, electrical wiring and plumbing. Safety, as well as efficiency of operation, must be considered when selecting the fireplace location. Try to select a location that does not interfere with room traffic, has adequate ventilation, and offers an accessible pathway for B-Vent & Combustion Air Kit installation.
SP28-F2 Modular Series Fireplace Installation Installing The Gas Line Installing The Remote Switch The gas line must be installed before finishing the fireplace. Natural Gas requires a minimum inlet gas supply pressure of 5.5" W.C. & a manifold pressure of 3.5" W.C. Propane Gas requires a minimum inlet gas supply pressure of 11" W.C. & a manifold pressure of 10" W.C. Provision must also be made for a 1/8" N.P.T.
SP28-F2 Modular Series Fireplace Installation Finishing Around the Fireplace Combustible mantels and mouldings may be safely installed over the top and on the front of the fireplace provided that they do not project beyond shaded area shown in Figure 5. Side wall clearances are 0". Combustible surrounds may be installed with 0" clearance to the side of the fireplace as shown in Figure 6. Fireplace Facing Mantels & Surrounds NOTE: Mantel clearances shown are for fire hazard prevention.
SP28-F2 Modular Series Fireplace Installation Installing Decorative Burner Trays The burner tray may be installed/upgraded before or after the EP28 outer shell has been installed. 1. Remove the lower trims. 2. If you are converting or upgrading an EP28 Series fireplace which has doors installed, you must first remove the doors. To remove the doors, push up firmly on the spring clip to release the top of the door.
SP28-F2 Modular Series Fireplace Installation EP28-F2 Logset Heat Circulating Blowers This model are supplied with five ceramic fibre logs and a package of silica sand. Unpack the logs and handle them very carefully. Some EP-28 Series decorative fireplaces may be equipped with an optional blower kit (Part # FAN28) for circulating heat into the living space. Pour the sand into the burner pan and spread it out evenly. Place the Back log in the sand as shown below in figure 9.
SP28-F2 Modular Series Fireplace Installation Optional Doors EP28 Series Decorative Models come standard with a firescreen, and may be fitted with one of the following optional door kits: n Twin-Pane-Style Doors ................ Part # ETW28 n Bi-Fold Doors ....................... Part # EBD28 n Stereo Cabinet Doors ................... Part # ETWD28E Twin-Pane and Bi-Fold Doors are available in Black, Brass or Nickel Finshes to match your fireplace's trim. Stereo Cabinet Doors are an allglass design.
SP28-F2 Modular Series Fireplace Installation 6. Cut the front bar to allow clearance to install the Heating Insert Using a hacksaw, make the cut approximately 2" in from the side of the firebox, as shown in figure 16. Install the Insert by pushing it all the way back inside the shell as shown in figure 19. Let the insert rest on the support ledges. Allow the efficiency collar to drop down and rest on top of the Insert. Figure 16. Cutting the front bar. 7.
SP28-F2 Modular Series Fireplace Installation 10. Reconnect gas line by following the information on page 4. 11. Turn on the gas supply and leak test the connection using a soap solution. 12. Install the new front bar as shown in figure 21. Figure 21. Installing the new front bar. 14. Remove the glass door as shown in Figure 23. Remove the plastic shipping ties and padding from the two bottom logs. Install the top logs as shown in Figure 8b and 8c. Re-install the door. Figure 23.
SP28-F2 Modular Series Fireplace Operation - Model EP28 EP28-4 with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas.
SP28-F2 Modular Series Fireplace Maintenance CAUTION n Fireplace gas control must be in the “OFF” position and pilot and main burners extinguished when cleaning appliance with a vacuum. Gas Control Valve n Glass and logs can get very hot. Handle only when cool. General n Have the fireplace installation inspected yearly, including a visual check of the vent system, the burner and the pilot flame. For your convenience a 1/8" manifold pressure tap is supplied on the gas valve for a test gauge connection.
SP28-F2 Modular Series Fireplace Maintenance Pilot Burner Adjustment 1. Determine which pilot is installed in the fireplace based on figures 25a and 25b. 2. Locate Pilot Adjustment Screw. (See figures 24a, 24b, and 24c.) Troubleshooting The following is a troubleshooting chart of possible problems: PROBLEM CORRECTIVE ACTION Noisy Pilot Flame Remove pilot adjuster cap, located on the gas control valve. Flame is decreased by turning adjustment screw clockwise.
SP28-F2 Modular Series Fireplace Warranty The Warranty The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a tenyear warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve and fibre logs. Glass, plated/painted finishes, and refractory lining are exempt.
SP28-F2 Modular Series Fireplace Notes XG0318 Page 15
XG0318 Rev. 00 03/2003 Canadian Heating Products Inc. Montigo Del Ray Corp.