Specification
MARK-IT BLUE Page 2 of 4 Issue Date: 1/14
SECTION 5. FIRE AND EXPLOSION HAZARDS
Flash Point: Not available.
Test Method: Not available.
LEL Flammable Limits: Not pertinent.
UEL Flammable Limits: Not pertinent.
Autoignition Temperature: Not pertinent.
Flammability Classification: None.
Known Hazardous Products of Combustion: None.
Properties that Initiate/Contribute to Intensity of Fire: None.
Potential For Dust Explosion: None.
Reactions that Release Flammable Gases or Vapors: Flammable hydrogen gas may be liberated
from contact with some metals.
Potential For Release of Flammable Vapors: None.
Unusual Fire & Explosion Hazards: Extinguish all nearby sources of ignition/spark.
Extinguishing Media: Dry powder or CO2.
Special Firefighting Procedures: Wear positive pressure, self-contained
breathing apparatus and goggles. Avoid
smoke inhalation. Contain any liquid runoff.
SECTION 6. SPILLS AND LEAKS
Containment: Prevent product spillage from entering drinking water supplies or streams.
Clean Up: Collect liquid or absorb onto absorbent material and package for disposal.
Evacuation: Not necessary.
SECTION 7. STORAGE AND HANDLING
Storage: Store in plastic or stainless steel container in a cool, well-ventilated, dry place at
temperatures above 40ºF. Avoid contact with active metals. Do not store near
food or feeds. Do not stack pallets more than two (2) high.
Transfer Equipment: Transfer product using chemical-resistant plastic or stainless steel tanks, pumps,
valves, etc.
Work/Hygienic Practices: Keep out of reach of children. Avoid contact with eyes, skin and clothing. Avoid
inhalation of spray mists. Wash thoroughly with soap and water after handling.
SECTION 8. PERSONAL PROTECTIVE EQUIPMENT
Eyes: Chemical dust/splash goggles or full-face shield to prevent eye contact. As a general rule, do
not wear contact lenses when handling.
Skin: Impervious gloves and clothes.
Respiratory: Not normally needed. If use generates an aerosol mist or respiratory irritation, use NIOSH-
approved dust/mist respirator (such as 3M #8710).
Ventilation: Recommended but no TLV established.