Installation Guide
TROUBLESHOOTING
1. Check blue wire from fan to make sure it is connected to hot wire from house.
2. Check for loose or disconnected wires in fan switch housing.
3. Check for loose or disconnected wires in light kit.
4. Check for faulty light bulbs.
CAUTION: Make sure main power is turned off before entering switch housing.
Light bulbs and glass installation
Install 3 x 50 watt JDE11 base bulbs, Bulbs included.
WARNING: Over lamping the fan will result in the fan lights
shutting down until the proper wattage of bulbs are installed.
Reset the lights by turning off the wall switch, breaker,or by
remote. Replace bulbs with the correct wattage bulbs, turn
the power on.
Caution: Do not replace bulb until it cools down.
Remove finial, final cap, hex nut, washer and rubber washer
from light fixture if they are preassembled on the light
fixture.
Raise glass in order to guide pull chains through appropriate
holes in glass (Note: Make sure the side with a label “This
side up” is installed upward), aligning threaded rod on light
fixture with hole in middle of the glass and push up gently
allowing threaded rod to come through hole. (Note: Be sure
pull chain for fan operation does not rub against bulb during
operation). Replace the rubber washer, washer and nut on
threaded rod, Tighten the nut but DO NOT OVERTIGHTEN as
glass may crack or break. Align hole in center of final cap
with thread rod, allowing pull chains to come through
appropriate holes in the final cap, and push up. Thread
center pull chain through hole in finial and secure glass to
light fixture by tightening the finial. DO NOT OVER TIGHTEN
the finial as glass may crack or break. (Fig.1)
Install fan pull chain and light kit pull chain to preassembled
pull chains on fan and light fixture. Pull chains provided.
(Fig.1)
When using fan remote or wall controller, make sure
light is on with pull chain and fan is set at high speed then
cut pull chain off. Cut off pull chains about 1 inch from
bottom of threaded pipe or glass so that they will fit in final
cap with one hole and finial without hole. Install the final cap
and finial to fitter. (Fig.2)
Bulb
Pull chain for light
Pull chain for fan
Reverse switch
Final cap
Final
Rubber washer
Washer
Hex nut
Glass
Fig. 2
Fig. 1
Final cap w/
one hole
Finial w/o hole
4
© 2014 Monte Carlo Fan Company
10/6/2014