Installation Sheet
4
© 2018 Monte Carlo Fan Company
10/2018
7 8 9
10
11
Install ball end of downrod into mounting 
bracket opening. Align (engage) slot on 
ball with tab on mounting bracket.
Warning: Failure to align slot on ball with 
tab may result in serious injury.
Important: If using the angle mount, 
make sure open end of mounting bracket 
is installed facing the higher point of the 
ceiling and make sure the ceiling angle is 
not steeper than 30º. 
For Canadian installation and for USA fan 
and light kit combinations over 35 lbs, in 
both flush and downrod modes the safety 
cable must be installed into the house 
structure beams using 3” lag screws, 
washers and lock washers provided. 
Make sure that when the safety cable is 
fully extended the lead wires are longer 
than the cable and no stress is placed on 
the lead wires.
Note: If Installing The Secondary Support 
Safety Cable in the U.S., Do Not Remove 
Knockouts In The Outlet Box.
Make wiring connections using wire 
connectors provided as indicated above. 
White from fan to White (Neutral) from 
house. Black and Blue from fan to Black 
(Live) from house. Connect all green 
grounded wires to Grounded wire from 
House. Make sure that no filaments are 
outside of the wire connectors.
After making the wire connections, the wires 
should be spread apart with the grounded 
conductor and the equipment-grounding 
conductor on one side of the outlet box and 
ungrounded conductor on the other side of 
the outlet box. The splices after being made 
should be turned upward and pushed carefully 
up into the outlet box. 
Lift Canopy allowing the 2 studs to 
protrude through the canopy.
Next lift the cover ring and install knurled 
nuts as shown. Tighten the knurled nuts 
securely. The canopy should adjust for 
any irregularity in the ceiling or Outlet 
box.
Make sure the studs protruding from the 
bottom of the Mounting bracket are 
installed with threads all the way through 
the bracket. 
SAFETY CABLE INSTALLATION
Lag screw
Safety cable
Washer
Lock washer
Tab
Slot
Go to step 19 to finish 
installation
Wall 
switch
Power
source
White
(Neutral)
Black
(Live)
Ground/Green
Black
Blue
White
Stud
Grounded
wires
Ungrounded
wires