Installation Instruction (Flushmount)
Remove canopy cover by turning counterclockwise. There are 6 holes 
on the bottom of the canopy, 3 of them are larger. (Fig. 5) 
Thread lead wires and safety cable through canopy. Place canopy over 
yoke, aligning larger holes in canopy with the 3 existing screws on top 
of motor housing. Install 3 screws and 3 lock washers (these screws 
and lock washers will be located in the hardware pack) into the 
remaining holes. Tighten all screws securely. (Fig. 5-1)
To prepare the fan for wiring, hang fan onto mounting bracket by 
sliding the canopy over the mounting bracket hook (Use one of 
non-slotted holes on the rim of the canopy). (Fig. 5-2)
Safety Cable Installation
For Canadian installation and for USA fan and light kit combinations 
over 35 lbs, in both flush and downrod modes the safety cable must 
be installed into the house structure beams using 3” lag screws, 
washers and lock washers provided. Make sure that when the safety 
cable is fully extended the lead wires are longer than the cable and no 
stress is placed on the lead wires. (Fig. 6)
Note: If Installing The Secondary Support Safety Cable in the U.S., Do Not 
Remove Knockouts In The Outlet Box.
SAFETY CABLE INSTALLATION
Lag screw
Safety cable
Washer
Lock washer
Fig. 5-1
Fig. 6
Fig. 5-2
yoke
Canopy
Screws 
Canopy
Hook
Lead wires and 
Safety cable