Instructions / Assembly
5
© 2015 Monte Carlo Fan Company
5/10/2015
12 13 14
15 16 17
Remove side covers from canopy 
exposing 4 holes. 2 closed holes and 2 
open “L” shape holes. 
Reinstall the 3 set screws remove in step 
11. Tighten screws securely. 
To prepare the fan for wiring, hang fan 
onto mounting bracket by sliding the 
canopy over the mounting bracket hook 
(Use one of non-slotted holes on the 
rim of the canopy).
For Canadian installation and for USA fan 
and light kit combinations over 35 lbs, in 
both flush and downrod modes the safety 
cable must be installed into the house 
structure beams using 3” lag screws, 
washers and lock washers provided. 
Make sure that when the safety cable is 
fully extended the lead wires are longer 
than the cable and no stress is placed on 
the lead wires.
Note
: If Installing The Secondary Support 
Safety Cable in the U.S., Do Not Remove 
Knockouts In The Outlet Box.
Make wiring connections using wire 
connectors provided as indicated above. 
White from fan to White (Neutral) from 
house. Black and Blue from fan to Black 
(Live) from house. Connect all green 
grounded wires to Grounded wire from 
House. Make sure that no filaments are 
outside of the wire connectors.
Place canopy and rubber pad over lead 
wire and safety cable and align the larger 
holes in canopy and holes on rubber pad 
with the set screws on yoke. 
Side cover
Rubber pad 
Lag screw
Safety cable
Washer
Lock washer
Hook
SAFETY CABLE INSTALLATION
Grounded/
Green
Wall 
switch
Power
source
White
(Natural)
Black
(Live)
Black
Blue
White